For use with R17D: Cap Adaptor Replacement Instructions
1. Take a tube with original Fa8 cap.
2. Pull out the Fa8 cap adaptor at both ends.
3. The pins of tube are aligned with the pins hole of R17d cap adapter, plug in R17d cap adaptor at both ends.
4. Complete the replacement from Fa8 to R17d cap.
WIRING INSTRUCTION: FA8 – ELECTRONIC BALLAST
NOTE: For Installations 220–277V with two hot leads, connect the second hot lead to the terminal N (L1)
WIRING INSTRUCTION: MAGNETIC BALLAST
© Copyright 2023 Satco Products, Inc. 10/23 v3
Retrofit luminaire with 1 lamp
Retrofit luminaire with 2 lamps
Retrofit luminaire Magnetic Ballast