Télécharger Imprimer la page

Enerco MR. HEATER MH55FAV Instructions D'utilisation Et Manuel Du Propriétaire page 8

Publicité

WIRING DIAGRAMS
THERMOCOUPLE
RELAY
B
W
G
LINE CORD
LEGEND
COLOR CODE
FEMALE CONN.
B
BLACK
RED
R
BLUE
Y
YEL
RING CONN.
BL
W
WHITE
O
ORG
TERMINAL BOARD
G
GREEN
WIRING CHART (Wire: Type AWG 150
55FAV, 85FAV, 125FAV
Color
Length
Black
6" (152mm)
Orange 11" (279mm)
White
4 1/2" (114mm)
Yellow
16" (406mm)
Yellow
16" (406mm)
Black
5" ((127mm)
White
5" (127mm)
Orange 6" (152mm)
Orange 6" (152mm)
Enerco Group, Inc.| Forced Air Propane Construction Heater
All manuals and user guides at all-guides.com
CONNECTION DIAGRAM
MOTOR
B
B
IGNITOR
I1
I2
W
B
HIGH-LIMIT SWITCH
R* or Y*
R* or Y*
B
W
NOTE:
IF ANY ORIGINAL WIRING AS SUPPLIED WITH THE HEATER MUST BE REPLACED, IT MUS BE REPLACED WITH
TYPE AWG 105° C WIRE OR ITS EQUIVALENT EXCEPT AS INDICATED (*TYPE SF 2-200, **SGI-250°C)
o
C or equivalent (Type SF2-200, **SGI-250
From
I1 (Ignitor)
1 (Ignitor
I2(Ignitor)
High Limit
High Limit
Relay
Relay
Relay
Relay
B
SPARK PLUG
B** or O**
MOTOR
115V
60HZ
To
T.B. Line
Spark Plug
T.B. Return
T.B. Middle
T.B. Line
T.B. Middle
T.B. Return
Thermocouple Junction Block
Thermocouple Junction Block
8
Operating Instructions and Owner's Manual
SCHEMATIC DIAGRAM
HIGH-LIMIT SWITCH
THERMOCOUPLE
SPARK PLUG
I1
IGNITOR
I2
RELAY
GAS
VALVE
o
C))
70056 Rev. A 5/05

Publicité