To operate: push ON button to turn fireplace on; push OFF button to
turn fireplace off.
!
NOTE: Remote control operates main power supply. Heat must
still be controlled by switches on fireplace.
Resetting The Temperature Cutoff Switch
Should the heater overheat, an automatic cut out will turn the heater off
and it will not come back on without being reset. It can be reset by
switching the Main ON/OFF Switch to OFF and waiting five (5) minutes
before switching the unit back on.
CAUTION: If you need to continuously reset the heater, unplug the
unit and call customer service at 1-888-346-7539.
Maintenance
WARNING: Always disconnect from the power supply before
attempting any maintenance.
Bulb Replacement
The bulbs are located behind the back panel.
To gain access to the bulbs:
1. Remove the silver screw that secures the access panel to the
firebox as indicated in Figure 3.
2. Remove and slide out panel.
3. Remove the defective lamp by unscrewing it as shown in Figure 4.
4. Replace with a 60 Watt E12 clear chandelier or candelabra. Take
care not to over-tighten the bulb.
5. Refit the access panel and secure with the screw removed in
step 1.
!
NOTE: To remove the firebox insert prior to repair, remove the five
(5) black screws at the back of the firebox as shown in Figure 3 and
slide it out to the front.