VENTING YOUR PELLET STOVE INTO AN
EXISTING CLASS A 6" CHIMNEY SYSTEM
IMPORTANT:
If you are installing your pellet stove as a
replacement to an existing wood stove, you
can install your pellet stove using the existing
class A 6" venting system.
1.
You must have the existing chimney system
cleaned and/ or inspected by a qualified
chimney sweep before proceeding with the
installation of your pellet stove.
2. To the right is an example of an installation
using part number 860001, 3-6" transition into
6" connector pipe. the illustration is only an
example. Please conform to any local building
codes or regulations having jurisdiction before
you have a qualified installer proceed with this
installation.
© 2022 United States Stove Company
Ceiling
Support
10
INSTALLATION
Existing Class 'A'
6" Chimney System
Support
Bracket
3" to 6" Pipe
Adapter
3" PL Vent
Clean Out Tee