Télécharger Imprimer la page

Publicité

Liens rapides

Owner's Instruction and Operation Manual
Model Number:
US5517-P
Report #: F22-777
Certified to ASTM E1509-12 (2017)
and Certified to ULC-S627-00-REV1
Mobile Home Approved
* All Pictures In This Manual Are For Illustrative Purposes Only. Actual Product May Vary.
Save These Instructions In A Safe Place For Future Reference.
SAFETY NOTICE: If this heater is not properly installed, a house fire may result. For
your safety, follow the installation instructions. Never use make-shift compromises
during the installation of this heater. Contact local building or fire officials about
permits, restrictions and installation requirements in your area. NEVER OPERATE
THIS PRODUCT WHILE UNATTENDED.
CAUTION! Please read this entire manual before you install or use your new room
heater. Failure to follow instructions may result in property damage, bodily injury, or
even death. Improper Installation Will Void Your Warranty!
U.S. Environmental Protection Agency
Certified to comply with 2020 particulate
emissions standards.
THIS MANUAL IS SUBJECT TO CHANGE WITHOUT NOTICE.
© 2022 United States Stove Company, 227 Industrial Park Rd., South Pittsburg, TN 37380
R
CALIFORNIA PROPOSITION 65 WARNING:
This product can expose you to chemicals including carbon
monoxide, which is known to the State of California to cause
cancer, birth defects, and/or other reproductive harm. For
more information, go to www.P65warnings.ca.gov
853925-2303L
Ph. 800-750-2723

Publicité

loading

Sommaire des Matières pour United States Stove US5517-P

  • Page 1 State of California to cause emissions standards. cancer, birth defects, and/or other reproductive harm. For more information, go to www.P65warnings.ca.gov THIS MANUAL IS SUBJECT TO CHANGE WITHOUT NOTICE. © 2022 United States Stove Company, 227 Industrial Park Rd., South Pittsburg, TN 37380 Ph. 800-750-2723...
  • Page 2 This app is available only Text to 423-301-5624 or; on the App Store for iPhone and iPad. Email us at: Search US Stove. Save your receipt with customerservice@usstove.com your records for any claims. © 2022 United States Stove Company...
  • Page 3 Declaration of Completion: As the qualified person responsible for the work described above, I confirm that the appliance as associated work has been installed as per manufacturer’s instructions and following any applicable building and installation codes. Signed: ______________________________________ Print Name: __________________________________Date: ______________ Home Owner: RETAIN THIS INFORMATION FOR FUTURE REFERENCE © 2022 United States Stove Company...
  • Page 4 CORD IN FOOT TRAFFIC AREAS OR PINCH THE CORD UNDER FURNITURE. US Stove highly recommends your stove be installed by a qualified NFI (US) or WETT (Canada) technician. To find the nearest qualified installer, go to: https://nficertified.org, https://www.wettinc.ca/ © 2022 United States Stove Company...
  • Page 5 458 mm F Back wall To Flue 3” 77 mm G Wall To Corner Of Appliance 2” 51 mm H Ceiling Height To Floor 60” 1524 mm J Ceiling Height To Appliance 27” 686 mm © 2022 United States Stove Company...
  • Page 6 The maximum recommend vertical venting height is 12- the floor of the home. feet for 3-inch type “PL” vent. Total length of horizontal © 2022 United States Stove Company...
  • Page 7 Vent surfaces can get hot enough to cause burns if touched by children. Noncombustible E. Minimum 2-foot (0.61m) clearance above any grass, shielding or guards may be required. plants, or other combustible materials. © 2022 United States Stove Company...
  • Page 8 4 inch “PL” pellet venting products. The use of other of vertical venting. An approved vertical vent cap is components other than stated herein could cause bodily recommended. harm, heater damage, and void your warranty. © 2022 United States Stove Company...
  • Page 9 If clearance through a combustible wall. Once outside the an offset is required, it is better to install 45-degree structure, a 3” (76 mm) clearance should be maintained elbows rather than 90-degree elbows. © 2022 United States Stove Company...
  • Page 10 Please conform to any local building codes or regulations having jurisdiction before you have a qualified installer proceed with this Support installation. Bracket 3” to 6” Pipe Adapter 3” PL Vent Clean Out Tee © 2022 United States Stove Company...
  • Page 11 • The levels of heat output will incrementally change on the bar graph starting from heat range “1” to heat range • When room temperature drops below desired set-point “5”. the stove will ramp back up until it reaches the desired temperature. © 2022 United States Stove Company...
  • Page 12 Maintaining smaller fires will This heater is designed to burn only PFI Premium grade © 2022 United States Stove Company...
  • Page 13 If the stove shuts down push the “On/Off” button to re-start your stove. The stove will have to fully shut down and turn off before you will be able to restart the stove. © 2022 United States Stove Company...
  • Page 14 DO NOT VACUUM HOT ASH. the fly ash out of the heat exchanger. WARNING: a. Open the door and remove the burnpot. FAILURE TO PROPERLY MAINTENANCE THE CLEAN OUTS WILL RESULT IN POOR PERFORMANCE OF THIS STOVE. © 2022 United States Stove Company...
  • Page 15 CHECK & CLEAN THE HOPPER be removed with a brush specifically designed for the Check the hopper periodically to determine if there is any type of chimney in use. A qualified chimney sweep can © 2022 United States Stove Company...
  • Page 16 5. Re-install the retainer and eight nuts and rope gasket Gaskets Inspected using high-temperature silicone to adhere the gasket Glass Wiped Cleaned to the door. Hopper (end of Empty & 6. Never use substitute materials for the glass. season) Vacuumed © 2022 United States Stove Company...
  • Page 17 If the other items check out OK, replace the high limit switch. ATTENTION: THIS WOOD HEATER NEEDS PERIODIC INSPECTION AND REPAIR FOR PROPER OPERATION. IT IS AGAINST FEDERAL REGULATIONS TO OPERATE THIS WOOD HEATER IN A MANNER INCONSISTENT WITH OPERATING INSTRUCTIONS IN THIS MANUAL. © 2022 United States Stove Company...
  • Page 18 (you may want to remove the hose entirely off the stove and the air switch first and make sure it is clear). If you hear a click, the air switch is working. BE CAREFUL TOO MUCH VACUUM CAN DAMAGE THE AIR SWITCH. © 2022 United States Stove Company...
  • Page 19 The control board is not sending power to the POF There should be a 5-volt (approximately) current going to the thermodisc or other auger system components. POF thermodisc after the stove has been on for 10 minutes. © 2022 United States Stove Company...
  • Page 20 Remove the auger motor from the auger shaft and try to run the The auger motor has failed. unit. If the motor will turn the shaft is jammed on something. If the motor will not turn, the motor is bad. © 2022 United States Stove Company...
  • Page 21 Circuit board malfunction. board is fine. If there is NOT power being sent to the blower when it shuts off during operation, then you have a bad control board. © 2022 United States Stove Company...
  • Page 22 Call 1-800-750-2723 Ext 5051 or Email to: parts@usstove.com IN ORDER TO MAINTAIN WARRANTY, COMPONENTS MUST BE REPLACED USING USSC PARTS PURCHASED THROUGH YOUR DEALER OR DIRECTLY FROM USSC. USE OF THIRD PARTY COMPONENTS WILL VOID THE WARRANTY. © 2022 United States Stove Company...
  • Page 23 Part numbers and descriptions can be found in the “Repair Parts” section of this manual. Once this information has been gathered you can contact customer service by phone 1-800-750-2723 Ext 5051 or Email parts@usstove.com. Model Information Model Number Serial Number © 2022 United States Stove Company...
  • Page 24 Engineer Name: ____________________________________ Engineer Name: ____________________________________ License No.: ________________________________________ License No.: ________________________________________ Company: __________________________________________ Company: __________________________________________ Telephone No.: _____________________________________ Telephone No.: _____________________________________ Stove Inspected: Chimney Swept: Stove Inspected: Chimney Swept: Items Replaced: ____________________________________ Items Replaced: ____________________________________ © 2022 United States Stove Company...
  • Page 25 NOTES © 2022 United States Stove Company...
  • Page 26 NOTES © 2022 United States Stove Company...
  • Page 27 NOTES © 2022 United States Stove Company...