Télécharger Imprimer la page

Fröling PE1 Pellet 20 Instructions De Montage page 19

Masquer les pouces Voir aussi pour PE1 Pellet 20:

Publicité

Sécurité
Marquages de sécurité
Notification concernant les procédures à adopter en cas d'urgence
EMERGENCY PROCEDURES
DANGER! In case of strong smell of flue gas!
Flue gases can cause fatal poisoning!
- Do not open any boiler doors or covers, or fuel transportation system door or covers!
- Turn off the boiler by pressing "Boiler OFF" ( )
- Air the room where boiler is installed!
- Close the door of the boiler room and doors to living areas!
DANGER! In the event of loss of electrical power!
- Do not open any boiler doors or covers, or fuel transportation system doors or covers!
- Boiler Control automatically restarts after power fail restart.
- Half an hour after power has returned, check system for normal operation and compare the pressure gauge
reading to initial settings. If system pressure is low, replenish water to the heating system according
plumber's instructions.
DANGER! In the event of runaway fire!
- Call the fire department!
- Turn off Emergency Switch, if installed.
- Do not open any boiler doors or covers, or fuel transportation system doors or covers!
- Do not switch off Main switch at Boiler!
- Evacuate your house.
- If possible, wet your entire roof with a garden hose.
- When there is no more risk of runaway fire, turn on Emergency Switch and resume to normal operation
of the system.
To cool overheated boiler (over 220°F / 105°C)!
- Turn off Emergency Switch, if installed.
- Do not open any boiler doors or covers, or fuel transportation system doors or covers!
- Turn off boiler by pressing "Boiler OFF" ( )
- Open all mixer taps, switch on all pumps.
- Leave the boiler room and close the door.
- Open all hot water faucets.
- Turn all thermostats in your house to their highest temperature settings and open all windows
if room heat is too hot
- When boiler temperature has dropped below 180°F (82°C), reverse the above steps.
- In case Safety Temperature Limit Switch automatically has been activated please refer to Owner's Manual.
Instructions de montage PE1 Pellet 20/35 | M2030017_fr-ca
PE1 Pellet – WOOD PELLET FIRED BOILER
2
A 2152 00 17
19

Publicité

loading

Ce manuel est également adapté pour:

Pe1 pellet 35