Télécharger Imprimer la page

Desa JourneyMan Serie Mode D'emploi page 7

Masquer les pouces Voir aussi pour JourneyMan Serie:

Publicité

Les langues disponibles

Les langues disponibles

When wiring to additional standard fixture
only: Strip the motion sensor's red wire and
connect to the standard fixture's black wire.
Connect all white wires together. Total fixture
ratings must not exceed 1000W (8.3 A).
NOTE: All wiring between fixtures should be run
in accordance with the National Electrical Code
through conduit or another acceptable means.
Contact a qualified electrician if there is any
question as to the suitability of the system.
WHITE from Line to
WHITE from JourneyMan
598-1007-02
Controlling Non-Motion Sensing Fixtures
BLACK from Switch to
BLACK from JourneyMan
®
Wiring to a Motion Light & Standard Fixture
Get other manuals https://www.bkmanuals.com
This fixture is provided with a sensor rated
for 1000W. Since the fixture is only rated 500W,
500W of additional load may be controlled by
this sensor.
When determining what a fixture is rated for,
do not simply look at the rating on the lamp in
the fixture. Look at the marking which speci-
fies the maximum lamp wattage for which the
fixture is suitable.
Once you have selected the fixtures to be con-
nected and determined their maximum ratings,
add these ratings up. For instance, if you have
3 fixtures rated 100W, 150W, and 75W respec-
tively, you have a total load of 325W.
®
RED from JourneyMan
BLACK from Fixture
WHITE from Line to
WHITE from Fixture
-7-
®
to
Standard
Fixture

Publicité

loading

Produits Connexes pour Desa JourneyMan Serie

Ce manuel est également adapté pour:

Journeyman hd-9260