c. Slide a small washer, spacer, small washer onto the axle
next to the wheel.
d. Slide the partially assembled axle through the wheel support
frame.
e. Slide the small washer, spacer, and small washer onto the
axle next to the wheel support.
f. Slide the wheel then large washer onto the axle and hold in
place with the remaining cotter pin.
g. Install the caps over the larger washers to finish the wheel
assembly.
2.
Position the heater on the wheel support frame assembly
with the exit opposite the wheels.
3.
Use eight screws and nuts to attach the handles to the top
of the tank flange. The screws will go through the handles,
tank flange and wheel support frame. Install the nuts and
finger tight only until all nuts are installed.
4.
Tighten all the nuts.
5.
Attach cord caddies to handles using No. (4) & No. (5)
screws and nuts.
Handle assembly for 125KT, 175KT& 210KT only.
ITEM
PART NO.
DESCRIPTION
1
24338
Handle, Front
2
24338
Handle,Rear
3
24339
Wheel Support Frame
4
26977
Machine Screw Blk (long)
5
26037
Kep Nut Blk
6
28746
Axle (125KT - 175KT)
28761
Axle (210KT only)
7
28752
Wheel (8'' Dia.)
221 10
Wheel (13'' Dia. 210KT only)
8
2875 1
Cap
9
28748
Spacer (125KT - 175KT)
28762
Spacer (210KT only)
10
28749
Washer, Large
1 1
28750
Cotter Pin
1 2
28754
Ext. Cord Caddy
1 3
27336
Machine Screw Blk (Small)
Enerco Group, Inc. | Kerosene Forced Air Heater
All manuals and user guides at all-guides.com
QTY
1
1
1
8
1 2
1
1
2
2
2
2
2
2
2
2
4
PREPARING FOR OPERATION
1.
Check the heater for possible shipping damage. If any is
found, immediately contact the manufacturer at
800-251-0001.
2.
Follow all of the "Precautions".
3.
Fill the fuel tank with clean kerosene. In extremely cold
weather, condensation may develop in the tank and it is
recommended that a tablespoon of de-icer be added for each
gallon (4 liters) of fuel in the tank. When filling the heater,
use at least 2 gallons (8 liters) of fuel. Be sure heater is level
and do not overfill. Use a funnel or can with a long fill spout.
IMPORTANT: Before filling fuel tank the first time or after
extended storage periods, drain the fuel tank of any moisture
or condensation.
4.
Locate heater at a safe distance from combustible materials.
Models 50K & 75KT is not suitable for use on wood floors or
other combustible materials. When used, the heater should
rest on suitable insulating material at least 1 inch thick and
extending 3 ft. or more beyond the heater in all directions.
HEATER START UP
1.
50K: Plug the heater into a grounded 115V, 60 Hz, 1 Ø outlet.
75KT, 125KT, 175KT & 210KT: Turn thermostat to lowest
setting, make sure "On/Off" switch is "Off". Plug the
heater into a grounded 115V, 60 Hz, 1 Ø outlet. Turn
thermostat to highest setting. Start heater by push toggle
switch to "On" position (light signifies switch is in "ON"
position). Adjust thermostat to desired setting. Heater will
cycle on/off as heat is required.
For all models:
• In cold weather (below 10° F), starting may be
improved by holding a finger over the vent hole of
the pump adjustment screw cap until the heater starts.
• This unit is equipped with an interrupt circuit. The
reset is located near the power cord. If the unit does
not start, press the reset button.
HEATER SHUT DOWN
50K: Unplug heater from power source.
1.
75KT, 125KT, 175KT & 210KT: Push "On/Off" switch
to "Off" position. For extended shutdown, unplug
heater from power source.
RESTART AFTER DIAGNOSTIC SAFETY SHUTDOWN
(50K, 75KT, 125KT, 175KT & 210KT) See page 7
Wait 5 minutes.
1.
2. Press reset button.
5
Operating Instructions and Owner's Manual
04/06
70276
Rev. B

Publicité