IC & NON-IC LED RECESSED
HOUSING FOR NEW CONSTRUCTION
Models: 80-980, 80-982
INSTALLATION AND SAFETY INSTRUCTIONS
IMPORTANT: Read before installing fixture. Retain for future reference.
WARNING: Risk of Fire or Electric Shock
• This fixture is for new construction applications only. All work must
be done by a certified electrician.
• TURN OFF the electrical power at fuse or circuit breaker box before
wiring fixture to power supply.
• Risk of electric shock, do not use where directly exposed to water.
IC housings can be installed in direct contact with insulation. Non–IC
housings must be kept 3 inches from any insulation.
• Damp location rated.
• This recessed fixture is intended to be connected to a properly
installed and grounded UL listed junction box.
INSTALLATION
1. FASTENING FIXTURE TO CEILING
Joist-type ceiling-extend bar hangers to fit between joists.
Position fixture temporarily by hammering "Nail" into joists.
(Figure A), then secure permanently with nails. Hangers
should be level with bottom of joists.
Suspended (T-bar) ceilings-extend bar hangers 1inch past
T-bars, then rest fixture on T-bars. Secure fixture to T-bars
with wire (Figure B).
A
2. ELECTRICAL CONNECTION
Housings without LED driver
Power Feed
Ground wire
Housings with LED driver
Junction box contains two wires. A
black (hot+) and a white (neutral-) which
must be spliced to the house current
feed wire. Make sure to splice white to
white and colored or black to black.
After splicing has been completed, tuck
splices carefully into junction box and
replace cover (Figure C).
© Copyright 2023 Satco Products, Inc. 1/23 v1.2
B
Connect -
Black - Supply Voltage
White - Neutral
Green Grounding J-Box Wire - Copper
or green grounding wire
C
Power Feed
IC
Type
Insulated Ceiling
The insulted ceiling or I.C. approved recessed
fixture is one that can be installed in direct
contact with insulation.
3. GROUNDING
For Romex or 3 wire BX flexible armour cable installations
attach supply ground lead (green) to bare copper ground
lead or ground screw in wiring box mounted on plaster
frame. Local electrical codes should be consulted to
determine acceptable installation-conduit Romex, or
flexible armour cable.
4. CUTTING A HOLE
Measure the inner diameter
of the can, then draw a circle
1/8 inch larger. Use a drywall
saw and carefully cut a hole to
install the fixture. (Figure D).
5. DIMMER SWITCH WIRING
Input Control Dimmer Switch
120V
WHITE (NEGATIVE)
RED (POSITIVE)
BLACK (LINE)
WHITE (NEUTRAL)
D
Input
Output
LED
Driver
Dimmer
Switch
Hole Cut Dimensions:
80-980 Round: ø117mm (4.625")
80-982 Round: ø149mm (5.875")
Satco Products, Inc.
Brentwood, NY 11717
LED PCB

Publicité

loading

Sommaire des Matières pour Satco NUVO 80-980

  • Page 1 80-982 Round: ø149mm (5.875") After splicing has been completed, tuck splices carefully into junction box and BLACK (LINE) replace cover (Figure C). WHITE (NEUTRAL) Satco Products, Inc. © Copyright 2023 Satco Products, Inc. 1/23 v1.2 Brentwood, NY 11717...
  • Page 2 CARCASA EMPOTRADA CON LED IC Y ESPAÑOL NO IC PARA NUEVA CONSTRUCCIÓN INSTRUCCIONES DE INSTALACIÓN Y SEGURIDAD Modelos: 80-980, 80-982 IMPORTANTE: Lea esto antes de instalar el accesorio. Consérvelo para referencia futura. ADVERTENCIA: Riesgo de Incendio y Descarga Eléctrica • Este accesorio es solo para aplicaciones de construcción nueva. Todo el trabajo debe ser realizado por un electricista certificado. •...

Ce manuel est également adapté pour:

Nuvo 80-982