3.2 CHECK THE OIL LEVEL
1.
Ensure the generator is on a level surface.
2.
Unscrew the oil cap and clean the dipstick.
3.
Check the oil level by reinserting the oil cap without screwing it back in.
Remove the cap and examine the oil level on the dipstick. If the level
is at or below the minimum oil level marked on the dipstick, refill to the
maximum oil level mark.
4.
Reinsert the oil cap and tighten securely.
NOTE
  Oil capacities:
ƒ BG4650E: 600 mL
ƒ BG6250E: 700 mL
ƒ BG11500E: 1.1 L
Maximum Oil Level
Minimum Oil Level
Maximum Oil Level
Minimum Oil Level