Télécharger Imprimer la page

Fermax 5282 Manuel D'installation page 13

Publicité

Les langues disponibles

Les langues disponibles

Cod. 97847 V06_17
USE OF A 4-STATE INPUT
A 4-state input (balanced loop) can detect the following situations:
-
Input active or inactive
-
Wire cut or short circuited (input sabotaged)
To use this input type, you must add two 4.7KOhm resistors (supplied with the module) on the
wires connecting the input to your detector (or other device).
To do that, use the following diagram:
4.7KOhm resistors
Detector
(or other)
Notes: each module input can be used in 2- or 4-state mode independently. You can configure
these modes from the "Technical" menu, "Site configuration" then clicking on the relevant mod-
ules.
3200292
All manuals and user guides at all-guides.com
Page 13/23

Publicité

loading