Installation
Place housing on base 6:
11.
-
Make sure that the electrical connection is in the desired position.
Secure threaded bolt 4.
-
12. Put upper cam 5 on the spindle 7.
13. Do electrical connections according to chapter 7 „Electrical Connections".
6.2
Diaphragm Valve with Stroke Limiter
1. Put valve in the «open» position using control pressure (FC, DA))
2. Remove indicator cap 1.
3. Screw the adapter 9 onto the locknut of the actuator.
4. Type ER 53:
-
Remove indicator cap. (Attention: indicator pin has left thread.)
Screw the intermediate piece 10 into the connecting piece.
-
Instruction for use