Télécharger Imprimer la page

Yamaha WR250F 2004 Manuel D'atelier Du Proprietaire page 309

Publicité

Charging method using a constant voltage charger
YES
Charge the battery until the charging
voltage reaches 15 V.
NOTE:
Set the charging time to a maxi-
mum of 20 hours.
Leave the battery unused for more than 30
minutes before measuring its open-circuit
voltage.
12.8 V → Charging is complete.
12.0 ~ 12.7 V → Recharging is required.
Under 12.0 V → Replace the battery.
CAUTION:
Constant amperage chargers
are not suitable for charging
MF batteries.
Measure the open-circuit
voltage prior to charging.
Connect a charger and
ammeter to the battery
and start charging.
Is the amperage higher
than the standard charg-
ing amperage written on
the battery?
Voltmeter
3 - 118
INSP
ADJ
ELECTRICAL
NOTE:
Leave the battery unused for
more than 30 minutes before
measuring its open-circuit voltage.
NO
This type of battery charger cannot
charge an MF battery. A variable
voltage charger is recommended.
Charger
Ammeter

Publicité

loading

Ce manuel est également adapté pour:

Wr250t 2004