Screws
Inlet
Filter
Outlet
Head
2. Assemble the Filtration System
Inspect the plumbing and supplies for damage. Replace or repair
as needed.
Write the system replacement date on the filter head label. This is
the installation date plus ten years.
Place the mounting bracket over the port marked "OUTLET" on
the filter head.
Attach the mounting bracket to the filter head using the screws
provided. Do not overtighten.
NOTE: Apply four layers (four turns) of thread sealant to the
threads of each nipple to ensure a tight seal.
Apply four layers of thread sealant to the threads below the hex
of each nipple.
Thread the taped end of each nipple into the inlet and outlet port
of the filter head until finger tight plus one turn maximum. Do
not tighten until the hex makes contact with the filter head.
Thread the larger end of the hoses onto the nipples until
wrench-tight. Do not overtighten.
Kohler Co.
All manuals and user guides at all-guides.com
Hoses
Nipples
Mounting
Bracket
Apply thread
sealant tape.
Filter Head
5
Hex
087388-2-AF