Télécharger Imprimer la page
Masquer les pouces Voir aussi pour PREASY 4222:
Les langues disponibles

Les langues disponibles

Displays
Programmable displays with a wide se-
lection of inputs and outputs for display of temperature,
volume and weight, etc. Feature linearisation, scaling,
and difference measurement functions for programming
via PReset software.
Ex interfaces
Interfaces
for
analogue
signals as well as HART
®
signals between sensors / I/P
converters / frequency signals and control systems in Ex
zone 0, 1 & 2 and for some modules in zone 20, 21 & 22.
Isolation
Galvanic isolators for analogue and digital
®
signals as well as HART
signals. A wide product range
with both loop-powered and universal isolators featuring
linearisation, inversion, and scaling of output signals.
Temperature
A wide selection of transmitters for DIN
form B mounting and DIN rail modules with analogue
and digital bus communication ranging from application-
specifi c to universal transmitters.
Universal
PC or front programmable modules with
universal options for input, output and supply. This range
offers a number of advanced features such as process
calibration, linearisation and auto-diagnosis.
All manuals and user guides at all-guides.com
and
digital
4 2 2 2
U n i v e r s a l
I / f C o n v e r t e r
N o . 4 2 2 2 V 1 0 0 - I N ( 0 8 4 5 )
F r o m s e r . n o . 0 6 0 8 6 7 0 0 1
S I G N A L S T H E B E S T
Side 1
DK
Page 25
UK
Page 49
FR
Seite 73
DE
loading

Sommaire des Matières pour PR electronics PREASY 4222

  • Page 27: Avertissements

    A la réception du module, vérifiez que le type de module reçu correspond à celui que Seule PR electronics SARL est autorisée à réparer le module vous avez commandé.
  • Page 28: Déclaration De Conformité

    PR electronics SARL, Zac du Chêne, Activillage, 4, allée des Sorbiers, F-69673 DECLARATION DE CONFORMITE Bron Cedex (tél. : (0) 472 140 607) ou à PR electronics A/S, Lerbakken 10, DK- 8410 Rønde, Danemark (tél. : +45 86 37 26 77).
  • Page 29: Démontage Du Systeme 4000

    All manuals and user guides at all-guides.com DEMONTAGE DU SYSTEME 4000 CONVERTISSEUR I/f UNIVERSEL PREASY 4222 Tout d’abord, n’oubliez pas de démonter les connecteurs où règnent des tensions dangereuses. • Entrées : RTD, TC, Ohm, potentiomètre, mA et V Figure 1 : •...
  • Page 30: Pr 4501 Indicateur / Façade De Programmation

    All manuals and user guides at all-guides.com PR 4501 INDICATEUR / Applications FAÇADE DE PROGRAMMATION Signaux d’entrée : Ten- Poten- tiomètre Courant sion RTD et R lin. Connexion, fils Fonctionnalité : Le menu simple, structuré à l’aide de questions pour la configuration du PReasy, guide automatiquement l’utilisateur par un menu déroulant et rend ainsi aisé...
  • Page 31: Références De Commande

    All manuals and user guides at all-guides.com REFERENCES DE COMMANDE : Immunité CEM ............. < ±0,5% de l’EC Immunité CEM améliorée : 4222 = Convertisseur I/f universel NAMUR NE 21, critère A, burst ......< ±1% de l’EC 4501 = Indicateur / façade de programmation Tensions auxiliaires : Alimentation 2-fils (borne 44...43) ....
  • Page 32: Configuration De La Détection Erreur Capteur

    All manuals and user guides at all-guides.com Entrée TC : Sortie PNP : max............ 30 mA Valeur Valeur sortie ............24 Vcc ±10% Type min. max. Standard sortie ............10 nF sortie +400°C +1820°C IEC 60584-1 typ............. 20 Ω sortie -100°C +1000°C...
  • Page 33: Limites De La Détection Erreur Capteur

    All manuals and user guides at all-guides.com Limites de la détection erreur capteur : CONNEXIONS : Détection erreur capteur (SE.BR, SE.SH) : Alimentation : Entrée Plage Affichage Limite CURR Rupture de boucle (4...20 mA) SE.BR <= 3,6 mA; > = 21 mA Ω...
  • Page 34: Schéma De Principe

    All manuals and user guides at all-guides.com SCHEMA DE PRINCIPE : PROGRAMMATION / OPERATION DES TOUCHES DE FONCTION Transmetteur 2-fils Courant Documentation pour le diagramme de programmation. Tension Généralités : Potentiomètre Lors de la configuration de l’indicateur / la façade de programmation vous êtes guidés tout au long des paramètres du menu ;...
  • Page 35 All manuals and user guides at all-guides.com Informations relatives au signal et erreur capteur sur la façade 4501 Langue : Dans le menu « lang.setup », vous pouvez sélectionner 7 différentes langues pour le texte d’aide. Choix entre : Anglais, allemand, français, italien, Erreur capteur (voir limites dans tableau) est affiché...
  • Page 36: Diagramme De Programmation

    All manuals and user guides at all-guides.com DIAGRAMME DE PROGRAMMATION Power up Si aucune touche n’est actionnée pendant 1 minute, l’indicateur retourne sur l’état défaut sans sauvegarde des modifications éventuelles apportées à la configuration. Incrémenter la valeur / choisir paramètre suivant Décrémenter la valeur / choisir paramètre précédent Valider les valeurs choisies et fin du menu ...
  • Page 37: Diagramme De Programmation

    All manuals and user guides at all-guides.com DIAGRAMME DE PROGRAMMATION Réglage avancé (ADV.SET) Continué de la page précédente 2.0 Dans le sous-menu simulation (SIM) il faut !'1. actionner pour retourner sur l’état defaut 1.0 " * ] ] . 11 1 4#  ...
  • Page 38: Menu Déroulant En Ligne 3 De L'indicateur

    Aller dans le menu de configuration avancée ? Sélectionner durée d’impulsion programmable [03] Sélectionner entrée température [20] Sélectionner Hz comme unité de sortie PREASY 4222 Sélectionner entrée potentiomètre Sélec. impulsions/minute comme unité de sortie Sélectionner entrée résistance linéaire Sélectionner impulsions/heure comme unité de sortie Sélectionner entrée courant Sélectionner impulsions/jour comme unité...
  • Page 51 All manuals and user guides at all-guides.com Subsidiaries PR electronics A/S tilbyder et bredt program af analoge og digi- France tale signalbehandlingsmoduler til industriel automation. Vores PR electronics Sarl Zac du Chêne, Activillage sales@prelectronics.fr kompetenceområder omfatter: Isolation, Displays, Ex-interfaces, 4, allée des Sorbiers tel.