Télécharger Imprimer la page

IFM Electronic Efector 200 OL Serie Notice Pour Utilisateurs page 11

Publicité

Les langues disponibles

Les langues disponibles

Programming the output function
Press for 10s.
Operation
Check the safe functioning of the unit. Display by LEDs.
LED green is lit
LED yellow is lit
LED red is lit
LEDs
yellow + red
Maintenance
Keep the plastic lenses of the sensor free from soiling.
For cleaning do not use any solvents or cleaning agents which could
damage the plastic lenses.
All manuals and user guides at all-guides.com
Unit is ready for operation.
Output is switched.
Error in object detection, e.g. maladjustment,
soiling of the lenses.
Flash alternately, 2 Hz: output short-circuited.
Flash alternately, 1 Hz: internal malfunction
(output is not switched).
The red LED starts to flash fast after
2s. Then the yellow and green LEDs
flash alternately. After 8s all LEDs go
off, the output function has chan-
ged from light-on mode to dark-on
mode (or vice versa).
11

Publicité

loading