2 While handling the unit:
▪ Keep both sides of the sling level.
▪ Keep your back straight.
3 After mounting the unit, remove the sling from the unit by pulling
1 side of the sling.
2.1.2
To remove the accessories from the
outdoor unit
1 Lift the outdoor unit. See
"2.1.1 To handle the outdoor unit" on
page 4.
2 Remove the accessories at the bottom of the package.
a
b
c
d
ENERG
ENERG
Y
IJA
IE
IA
a
Outdoor unit installation manual
b
Fluorinated greenhouse gases label
c
Multilingual fluorinated greenhouse gases label
d
Energy label
e
Product fiche data for room temperature control
f
Unit mounting plate
g
Bolts, nuts, washers, spring washers and wire clamp
3
Preparation
3.1
Preparing the installation site
WARNING
The appliance shall be stored in a room without
continuously operating ignition sources (example: open
flames, an operating gas appliance or an operating electric
heater).
3.1.1
Installation site requirements of the
outdoor unit
Mind the following spacing guidelines:
ERGA04~08DAV3
Daikin Altherma – Low temperature split
4P489913-1B – 2017.10
All manuals and user guides at all-guides.com
e
f
g
Y
IJA
IE
IA
>250
>350
b
a
(mm)
a
Air outlet
b
Air inlet
The outdoor unit is designed for outdoor installation only, and for the
following ambient temperatures:
Cooling mode
Heating mode
3.1.2
Additional installation site requirements
of the outdoor unit in cold climates
In areas with low ambient temperatures and high humidity, or in
areas with heavy snowfall, remove the suction grille to ensure proper
operation.
Non-exhaustive list of areas: Austria, Czech Republic, Denmark,
Estonia, Finland, Germany, Hungary, Latvia, Lithuania, Norway,
Poland, Romania, Serbia, Slovakia, Sweden, ...
1
3
2
a
Suction grille
Protect the outdoor unit against direct snowfall and take care that the
outdoor unit is NEVER snowed up.
c
a
Snow cover or shed
b
Pedestal
c
Prevailing wind direction
d
Air outlet
e
EKFT008D option kit
3 Preparation
b
>250
a
>250
(mm)
10~43°C
–25~25°C
a
a
c
b
e
Installation manual