ARF868 Radio Modems - Guide utilisateur / User guide version V2.2.3
2.3. Radio specifications
2.3.1 Introduction to the radio requirements
The modems use the European frequency band 863-870MHz. This frequency band is segmented into different sub-bands each with their own
regulatory requirements both in terms of power, spectral bandwidth, and use of the spectrum. ARF868 modems accept these regulatory require-
ments.
FR
2.3.1.1
Sub-bands
Each sub-band is defined by a minimum and maximum frequency. In addition, the maximum authorised power and the maximum Duty Cycle are
defined separately for each sub-band.
2.3.1.2
Duty Cycle
EN
The purpose of the Duty Cycle ratio is to make sure that no application can occupy a frequency band for more than a certain percentage of the
time. The duty cycle defines a maximum percentage of time (expressed in percentages of any period of hours during which a modem is au-
thorised to transmit. The limitation of the duty cycle should be monitored by the terminal equipment connected to the modem. Please contact
adeunis® for your calculations of your "air" occupation time.
2.3.1.3
Schematic representation of the requirements of the 863-870MHz frequency band
The table below is a schematic representation of the use of the 863-870MHz frequency band as used by the ARF868 model.
Caution: this table is non-contractual and is subject to changes in regulations.
2.3.2 ARF868 modem operating modes
ARF868 modems have two operating modes:
1 standard mode dedicated to very long ranges and for which immunity to jammers is optimum.
1 ARFx3Pro mode which ensures "air" compatibility with the whole of the ARFx3Pro modem range.
The default communication mode is the standard mode. As soon as it is switched on the modem is capable of transmitting and receiving data
with the parameters in its memory (*).
By default, the modem is in permanent listening mode of the RF interface and the UART port.
As soon as a frame from the RF link is demodulated, its content is transmitted to the UART port
As soon as a character chain is detected on the UART port, it is transmitted to the RF link.
(*): On first switching on the parameters are the default parameters (or factory settings). At subsequent switching on the parameters used are
those last memorised with the AT&W command (see § 5.2 AT Commands).
Power (mW)
500
25
SRD
1%
10
5
SRD
SRD
10%
0.1%
SRD : Short Range
Devices
SRD
0.1%
SRD
100%