Thermostat Schedule; Troubleshooting - Emerson 1F83C-11PR Instructions D'installation Et D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

THERMOSTAT SCHEDULE / PROGRAMMING
Energy Saving Factory Schedule
This thermostat is programmed with the energy saving settings shown in the table below for
all days of the week.
Heating Schedule
Cooling Schedule
Note: Thermostat can be programmed on or off the subbase
Modify the Heating Schedule
1.) Slide the system switch to Heat
2.) Press Menu
3.) Press Next to enter the schedule
4.) The time icons will flash – use
5.) Press Next – the set point icons will flash – use
current period
6.) Continue to press Next to advance through all periods (
Sleep) for all days of the week.
P4/
Note: Press Back to return to the previous setting. Once all days of the week have been
programmed the thermostat will display End. Press Exit at any time to save changes
and return to home screen.
Modify the Cooling Schedule
1.) Slide the system switch to Cool
2.) Repeat steps 2-6 from the heating schedule
Symptom
No Heat/
No Cool/
No Fan
(common problem)
No Heat
(Troubleshooting continued on next page)
For tips on programming your thermostat to receive
optimal comfort, convenience and energy savings go
to: thermostathelper.com
P1/Wake
6:00 AM - 70°F
6:00 AM - 78°F
or

TROUBLESHOOTING

Possible Cause
1.) Blown fuse or tripped circuit
breaker
2.) Furnace power switch to OFF
3.) Furnace blower compartment
door panel loose or not
properly installed
4.) Loose connection to
thermostat or system
1.) System Switch not set to
Heat
2.) Loose connection to
thermostat or system
3.) Heating System requires
service or thermostat
requires replacement
P2/Leave
P3/Return
8:00 AM - 62°F
5:00 PM - 70°F
8:00 AM - 85°F
5:00 PM - 78°F
to set the time for the start of a period
or
Corrective Action
1.) Replace fuse or reset breaker
2.) Turn switch to ON
3.) Replace door panel in proper position to engage
safety interlock or door switch
4.) Tighten Connections
Verify thermostat and system wires are securely
attached.
Diagnostic: Set System Switch to Heat and raise
the setpoint above room temperature. Within five
minutes the thermostat should make a soft click
sound and "Heat On" should appear on display.
This sound indicates the thermostat is operating
properly. If the thermostat does not click, try the
reset operation listed below. If the thermostat does
not click after being reset, contact your heating and
cooling service person or place of purchase for a
replacement. If the thermostat clicks, contact the
furnace manufacturer or a service person to verify
the heating system is operating correctly.
P4/Sleep
10:00 PM - 62°F
10:00 PM - 82°F
to set the temperature for the
Wake,
Leave,
P1/
P2/
Return,
P3/
7

Publicité

Table des Matières
loading