Télécharger Imprimer la page

IFM Electronic Efector 300 SI1004 Notice D'utilisation page 29

Publicité

Les langues disponibles

Les langues disponibles

I I Monitoring excess flow
With this function the position of the display window within the
detection range can be defined: Shift the LED for the maximum dis-
play value to position 8, 7, 6 or 5. In the case of maximum flow all
LEDs from 0 up to this LED are lit. The LEDs above the range signal
excess flow. If the switch point is above this range, the unit switches
in the case of excess flow.
0
LO
0
1
2
3
4mA
maximum flow
The output signal indicates the maximum flow and excess flow. The
output current for maximum flow/excess flow depends on the
position to which the LED for the maximum display value has been
shifted.
LED for maximum value
LED 5
LED 6
LED 7
LED 8
30
sensor
signal
HI
4
5
6
7
8
9
20mA
excess flow
output signal for
maximum flow [mA]
12.0 ... 13.6
13.6 ... 15.2
15.2 ... 16.8
16.8 ... 18.4
output signal for
excess flow [mA]
13.6 ... 20
15.2 ... 20
16.8 ... 20
18.4 ... 20