4. Remove valve and tube with needle-nose pliers.
(See Figure 26)
Valve and Tube
PISTON REPLACEMENT
1. Remove screws and nut with an 8 mm Spanner
wrench and a 4 mm Allen wrench. (See Figure 27)
2. Remove magazine assembly. (See Figure 28)
Magazine Assembly
3. Loosen set screw with a 3 mm Allen wrench to
unlock the adjusting rod.
4. Slide linkage mechanism and adjusting rod
simultaneously from collar.
PAGE 7 OF 24
OPERATION CONTINUED
5. Loosen collar with a 3 mm straight rod to remove the
spring. (See Figure 29)
Figure 26
6. Loosen screw with a 3 mm Allen wrench and
remove the block through the window.
7. Loosen screws with a 3 mm Allen wrench and
remove the cap. (See Figure 30)
Figure 27
8. Remove the piston assembly with a
10 mm spanner wrench. (See FIgure 31)
Figure 28
9. Remove piston and replace.
Figure 29
Figure 30
Figure 31