Télécharger Imprimer la page

Canarm A2X Serie Manuel D'instructions page 3

Publicité

Les langues disponibles

Les langues disponibles

A2X SERIES
SPUN ALUMINUM EXHAUSTERS
EC (Electronically Controlled) MOTOR SPEED CONTROL
EC motors are equipped with a control module that allows for accurate
manual adjustment of motor speed. Motor speed range is from 300 to
1800rpm or maximum rpm for that model.
The control module features a 4 digit LED display that indicates %
demand of full speed and motor speed in rpm. The display also indicates
an error code message for minor diagnostics if required.
MESSAGE DISPLAYED...
Spd- followed by the instantaneous speed in rpm
dE-
followed by S + demand in %
E1-
No communications
E2-
Under Voltage
Motor speed can be changed by adjusting the speed control pot located
on the control module. A small screwdriver can be used to make the
speed adjustment.
AC Supply - 115/208-230VAC
Power is connected to the motor and control module through
the junction box and wiring harness provided.
Note: For 115VAC operation the blue jumper provided (taped
to wire harness) must be inserted into motor power
connector. See diagram.
Caution: Operating the motor at 208-230VAC with the jumper will cause significant damage to the motor.
Note: EC motors have a soft start feature. When the power is turned on the control module gathers information from the motor then begins
the start up process. After a few seconds the motor will start to turn and reach full set speed in 10-15 seconds.
Remote Speed Control Option (please contact factory for further information)
UL762 RESTAURANT EXHAUST APPLICATION
All up-blast models are UL/cUL listed, they are capable to meet UL762 for Commercial Kitchen application:
The National Fire Protection Association (NFPA) publication NFPA 96 is the primary source for this application. Also consult local
authorities for all other applicable codes and guidelines before installation.
Exhaust fans used in kitchen ventilation applications must have external wiring. (Wiring must not be installed in the airstream).
Installation must include a means for inspecting, cleaning and servicing the exhaust fan. (Curb hinge, grease collector and outdoor
disconnect switches are available for purchase as accessories)
No dampers can be used in the system.