A2X SERIES
SPUN ALUMINUM EXHAUSTER
OPERATION INSTRUCTIONS AND PARTS MANUAL
READ AND SAVE THESE INSTRUCTIONS
The purpose of this manual is to aid in the proper installation and operation of the blowers. These instructions are intended to supplement good
general practices and are not intended to cover detailed instruction procedures.
IT IS THE RESPONSIBILITY OF THE PURCHASER TO ASSURE THAT THE INSTALLATION AND MAINTENANCE OF THIS EQUIPMENT IS
HANDLED BY QUALIFIED PERSONNEL.
Inspect all shipments carefully for damage. THE RECEIVER MUST NOTE ANY DAMAGE ON THE CARRIER'S BILL OF LADING AND FILE A
CLAIM IMMEDIATELY WITH THE FREIGHT COMPANY.
DO NOT LIFT THE UNIT BY THE HOOD OR MOTOR. PLEASE LIFT THE UNIT BY HORIZONTAL SUPPORTS.
GENERAL SAFETY
1. Now UL762 approved with guard.
2. All electrical work must be done in accordance with all applicable electrical codes by a
qualified electrician.
3. Prior to wiring ensure the power supply is locked in the OFF position and that the motor
nameplate voltage matches the supply voltage.
4. Do not install or operate this fan in an environment where combustible materials, gases or
fumes are present.
5. Caution: the fan contains rotating parts and electrical service. Appropriate safety
precautions should be taken during installation, operation and maintenance.
When servicing the fan motor may be hot, allow time for cooling down.
6. Before starting the unit, ensure the wheel rotates freely.
7. Check and tighten where necessary all nuts, bolts & set screws prior to fan start up (as
some may have loosened during shipment).
8. Please follow all applicable national, state/provincial and local codes, all of them will
supersede this manual.
9. Failure to follow the safety instructions in this manual may cause serious injury or
death due to electrical shock or high speed rotating parts.
DIMENSION & COMPONENT
WHEEL
MODEL
DRIVE
DIA.
A2X105
10.5"
DIRECT
A2X120
12.25"
DIRECT
A2X135
13.5"
DIRECT
A2X150
15"
DIRECT
M-A2X 04/11/19
A
B
C
D
19"
13.0"
21.633
13.125"
19"
13.0"
23.063
15.313"
21"
17.25"
24.027
16.875"
21"
17.25"
25.093
18.750"
E
A
19.852"
UPBLAST
23.160"
25.523"
28.359"
A
UPBLAST
DOWNBLAST
E
D
C
B
A
DOWNBLAST
E
D
A
SECTION A-A
Page 1 of 5
C

Publicité

loading

Sommaire des Matières pour Canarm A2X Serie

  • Page 1 A2X SERIES SPUN ALUMINUM EXHAUSTER OPERATION INSTRUCTIONS AND PARTS MANUAL READ AND SAVE THESE INSTRUCTIONS The purpose of this manual is to aid in the proper installation and operation of the blowers. These instructions are intended to supplement good general practices and are not intended to cover detailed instruction procedures. IT IS THE RESPONSIBILITY OF THE PURCHASER TO ASSURE THAT THE INSTALLATION AND MAINTENANCE OF THIS EQUIPMENT IS HANDLED BY QUALIFIED PERSONNEL.
  • Page 2 A2X SERIES SPUN ALUMINUM EXHAUSTERS INSTALLATION Install roof curb, caulk and flash to ensure the water tightness. Rotate the blower wheel by hand. Wheel should not be rubbing against the housing inlet. If rubbing occurs, loosen the set screws on the wheel hub and shift the wheel to obtain clearance.
  • Page 3 A2X SERIES SPUN ALUMINUM EXHAUSTERS EC (Electronically Controlled) MOTOR SPEED CONTROL EC motors are equipped with a control module that allows for accurate manual adjustment of motor speed. Motor speed range is from 300 to 1800rpm or maximum rpm for that model. The control module features a 4 digit LED display that indicates % demand of full speed and motor speed in rpm.
  • Page 4 A2X SERIES SPUN ALUMINUM EXHAUSTERS UP-BLAST UL762 RESTAURANT EXHAUST INSTALLATION UP-BLAST WALL MOUNTED UL762 RESTAURANT EXHAUST INSTALLATION WALL DISCONNECT MOUNTED OUTSIDE OF THE HOUSING, WIRED THROUGH THE VENT TUBE BY OTHERS WALL MOUNT BRACKET (OPTIONAL) WIRED TO POWER VENTED CURB RECOMMENDED WELDED DUCT BY OTHERS...
  • Page 5 WARRANTY CANARM Ltd. warrants every new fan to be free of defects in material and workmanship to the extent that, within a period of one year from the date of purchase CANARM Ltd. shall either repair or replace at CANARM’s option, any unit or part thereof, returned freight prepaid, and found to be defective.
  • Page 6 SERIE A2X ÉVACUATEUR EN ALUMINIUM REPOUSSÉ MODE D’OPÉRATION ET LISTE DES PIÈCES LIRE ET GARDER CES INSTRUCTIONS Le but de ce livret et de vous faciliter dans l’installation et l’opération de souffleurs. Ces instructions doivent complémenter des bonnes pratiques générales et ne sont pas conçus pour couvrir les procédures détaillées. IL EST LA RESPONSABILITÉ...
  • Page 7 SERIE A2X ÉVACUATEUR EN ALUMINIUM REPOUSSÉ INSTALLATION Posez le rebord, le scellant et la membrane pour assurer l’étanchéité. Tournez la roue du souffleur à la main. La roue ne doit pas frotter contre le boîtier. Si il y a un frottement, dévissez la vis sur le moyeu de la roue et déplacer la roue pour la dégager.
  • Page 8 SERIE A2X ÉVACUATEUR EN ALUMINIUM REPOUSSÉ Contrôle de la Vitesse de Moteur EC (Contrôlé électroniquement) Les moteurs EC sont équipés d’un module de commande qui permet un réglage manuel précis de la vitesse du moteur. La plage de vitesse contrôle de la vitesse du moteur est comprise entre 300 et 1800 rpm ou la vitesse de rotation maximale pour ce modèle.
  • Page 9 SERIE A2X ÉVACUATEUR EN ALUMINIUM REPOUSSÉ INSTALLATION DE L’ÉVACUATEUR DE RESTAURANT UL762 INSTALLATION DE L’ÉVACUATEUR MURAL DE RESTAURANT UL762 À DÉBIT VERS LE HAUT À DÉBIT VERS LE HAUT WALL INTERRUPTEUR DE FERMETURE INSTALLÉ À L’EXTÉRIEUR DU BOÎTIER, DISCONNECT MOUNTED CÂBLÉ...
  • Page 10 Canarm Ltée. garantie que tout nouveau ventilateur est libre de toutes défectuosités dans les matériaux et la main-d’œuvre, et ce pour une période d’un an à partir de la date d’achat. Durant cette période, CANARM LTÉE. réparera ou remplacera à la discrétion de CANARM, tout appareil ou pièce d’appareil, retournez à...

Ce manuel est également adapté pour:

A2x105A2x120A2x135A2x150