Télécharger Imprimer la page

CAME SMA220 Traduction De La Notice Originale page 8

De boucle inductive pour portails industriels, barrières automatiques, équipements de parkings et bornes escamotables

Publicité

Les langues disponibles

Les langues disponibles

5
Simulation mode
Changeover to simulations mode
Changeover to simulation mode:
Press the Sim1 + Sim2 buttons
simultaneously for 2 seconds.
Simulation mode:
Activation of the loop
Activation of the output relay
Alarm output activation
Inductance of loop 1
Inductance of loop 2
Exiting simulation mode
6
Troubleshooting
If an error occurs, operating mode «A» and error display «E» light up alternately and an error code such as E 012 is displayed. The LED changes to
flashing red, the 4 most recent errors are stored and can be interrogated.
Display
E001
Interruption
Error
Loop 1
Briefly pressing the «Data» button shows the last of 4 errors on the display. Another short press switches to the error before that, and so on. When
the button is pressed for the 5th time, the device switches back to automatic mode. If you press the «Data» button for 4 seconds during the query,
all error messages are deleted. The figure shows memory slot 1 in which error 001, Interruption loop 1, has been stored (example).
7
Reset
Reset 1 (recalibration)
Mode
The loop(s) is/are recalibrated.
Sim1
2 seconds
Most important technical data
8
Supply voltage /
Power consumption
Loop inductance
Loop connection wiring
Loop resistance
Output relay (loop)
Output relay (alarm)
Dimensions
Housing mounting
Connection type
Protection class
Operating temperature
Storage temperature
Air humidity
SAFETY INSTRUCTIONS
It is the responsibility of the manufacturer to perform a risk assessment and install the detector and the door system in accordance with applicable national and international
regulations and safety standards and, if applicable, in accordance with the Machinery Directive 2006/42/EC.
The detector may be installed by professionally qualified personnel only. Repairs or attempted repairs by unauthorised personnel will void the warranty. Do not touch the electrical and
optical components.
Came S.p.A.- Via Martiri Della Liberta 15 - IT-31030 DOSSON DI CASIER (TV)
TEL (+39) 0422 4940 - FAX (+39) 0422 4941 - info@came.com - www.came.com
Came S.p.A. hereby declares that SMA/SMA2/SMA220 complies with the essential requirements and other relevant provisions of the RoHS Directives 2011/65/EU,
R&TTE 1999/5/EC (until 12/06/2016), RED 2014/53/EU (after 13/06/2016).
Original upon request.
COMMERCIAL PRODUCT
4
Press «Sim1»
Press «Sim2»
button
button
Mode
Data
Sim2
Sim1
2 seconds
2 seconds
Data
1
Sim2
Mode
Data
1
Sim1
Sim2
Mode
Data
Sim1
Sim2
Mode
1
Sim1
Mode
2
Sim1
Mode
1
2
Sim1
2 seconds
E002
E011
E012
Interruption
Short circuit
Short circuit
Loop 2
Loop 1
Loop 2
SMA / SMA 2 / SMA 220
SMA / SMA 2
24 VAC -20 % to +10%, max. 2 VA
24 VDC -10 % to +20%, max. 1.5 W
SMA 220
100-240 VAC ± 10%, 50/60 Hz, max. 2.9 VA
max. 20 to 1000 µH,
ideally 80 to 300 µH
At 20-40 µH: max. 100 m at 1.5 mm
At >40 µH: max. 200 m with 1.5 mm
min. twisted 20x/m
< 8 Ohm with connection wire
max. 240 VAC; 2 A / 30 VDC; 1 A; AC-1
max. 40 VACDC; 0.3 A; AC-1
22.5 x 94 x 88 mm (B x H x T)
Direct DIN rail mounting
Plug-in terminals
IP 20
-20°C to +60°C
-40°C to +70°C
<95% non-condensing
Press «Sim2»
Press «Sim2»
button
button
1
Mode
1
2
Sim1
1
Mode
2
Sim1
E101
E102
E201/E202 E301
Under -
Over-
Saving
voltage
voltage
error
Mode
Data
Sim1
Sim2
8 seconds
2
2
Notes
L0 -
L1 -
No loop activation (time functions are active)
Data
2
Loop activation (time functions are active)
Sim2
- Loop 1
- Loop 2
0 -
0
1 -
Activation of output
Data
0
2
Sim2
Activation of output
- Loop 1
- Loop 2
A0
A1
-Switch off alarm relay
Switch on alarm relay
-
Measurement of the inductance, value in
Measurement of the inductance, value in
Return to function mode
E302
E311
Loop 1
Loop 2
Loop 1
too large
too large
too small
Reset 2 (factory setting)
All values (except the error memory) are reset to the factory
settings (see Table 4.11a). The loop(s) is/are recalibrated.
µH
µH
E312
Loop 2
too small

Publicité

loading

Ce manuel est également adapté pour:

Sma2Sma009sma2009sma009sma220