Télécharger Imprimer la page

GE D20A6 Mode D'emploi page 20

Publicité

All manuals and user guides at all-guides.com
General Data
I/O scan time ________________________________ 2ms
Internal power supply from the drive _____________ +5VDC, ±18VDC
N
!
OTE
Digital Inputs
Input type __________________________________ Voltage/Optocoupled
Inputs no. __________________________________ 12 (3 groups of 4 inputs)
0V connection _______________________________ different 0V for the groups
Voltage input value ___________________________ 15 up to 30V
Current input value ___________________________ 4.5 up to 9mA
Voltage input range High level (on pin) ) (U
Voltage input range Low level (on pin) ) (U
Digital Outputs
Output type _________________________________ open emitter/Optocoupled
Pull down __________________________________ 10 k Ω
Outputs no. _________________________________ 8
Connection _________________________________ common Ext supply
External power supply ________________________ 15 up to 30VDC
Output current ______________________________ 50mA max for any output
Output voltage (U
High
Analog Inputs
Input type (differential) ________________________ Voltage or Current
Inputs no. __________________________________ 2
Connection _________________________________ differential
Input voltage (with Voltage ref in input) ___________ ±10V
Current requirements (with Voltage ref in input) ____ <0.5mA
Input current (with current ref in input) ___________ 0 up to 20mA/4 up to 20mA
Input impedence (with current ref in input) _________ 510 Ω
Bandwidth __________________________________ 100Hz
20
—————— I/O Expansion card ——————
GEI-100427A
The Drive TB can be used to supply 24VDC power. AV-300i
24VDC supply maximum output = 120 mA total including
Encoder, LAN, EXP card and DGF. (or 350 mA without DGF)
High
Low
) _________________________ Power supply less 1V @50mA
) _______ ≥ 10V
) _______ ≤ 3V

Publicité

loading