Télécharger Imprimer la page

GEV Com Boy CVS Mode D'emploi page 4

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 5
CVS video door intercom for 2 to 6 apartments
Operating elements
Connection elements
Indoor monitor (fi g. A)
Indoor monitor (fi g. C)
1 Microphone
1 Power supply connector
2 Volume adjustment
2 Power supply terminal
3 Screen
3 Outdoor monitor connection
4 Talk button
4 Outdoor monitor connection
5 Monitoring
5 Floating relay contact
6 Monitor OFF
(Normally Open)
7 Open door button
6 Floating relay contact
8 LED status indicator
(Normally Open)
9 Loudspeaker
7 External bell
10 Ring tone volume adjustment
8 External bell
11 ON/OFF switch
9 Storey bell button
12 Ring tone selection/OFF
10 Storey bell button
13 Brightness
11 Additional indoor monitor
14 Color
15 Video connection
Outdoor monitor (Fig. D)
Door opener relay positive connector (+)
Outdoor monitor (fi g. B)
Door opener relay negative connector (-)
2 to 6 apartments
1 Indoor monitor 1 connection <> C3
1
1 Camera
2 Indoor monitor 1 connection <> C4
2 Infrared LED
1 Indoor monitor 2 connection <> C3
2
3 Loudspeaker
2 Indoor monitor 2 connection <> C4
4 Bell (2 to 6)
1 Indoor monitor 3 connection <> C3
3
5 Label (2 to 6)
2 Indoor monitor 3 connection <> C4
6 Microphone
1 Indoor monitor 4 connection <> C3
4
7 Volume adjustment (at rear)
2 Indoor monitor 4 connection <> C4
1 Indoor monitor 5 connection <> C3
5
2 Indoor monitor 5 connection <> C4
Power pack (fi g. E) 1 to 6
1 Indoor monitor 6 connection <> C3
6
1 Plug
2 Indoor monitor 6 connection <> C4
Safety information
All warranty claims will be null and void in the event of any
damage or loss caused by failure to observe these operating
instructions. We accept no liability for any consequential losses
or damage. We accept no liability for any personal injury or
material
damage
caused
by
improper
use
or
by
observe the safety advice. In these cases the guarantee and warranty are
invalidated. For safety and authorisation purposes it is not permitted to
carry out any adaptation or conversion of the device.
Installation
If in any doubt, rather than mounting, connecting or installing the
equipment yourself, contact a qualifi ed technician.
The
outdoor
unit
is
designed
for
fl ush-mounting.
mounting is possible using housing (available as an accessory). When
deciding where to install the outdoor monitor, choose a position that is
well protected against the elements, particularly rain. If necessary, use
waterproof housing to protect the device. The camera (B1) should face
upwards. Refer to the information on the optimal camera position (fi g. D).
Remove the cover (fi g. F1) and install the outdoor monitor according to
fi g. F2. Fit the seal so that the open ends face downwards. Carefully
remove the cover (fi g. F3) to write on the label.
Install the indoor monitor according to fi g. G.
Connection
Connect the door intercom according to fi g. H.
Connection accessories: see additional sheet.
Video connection
You can connect a television or video recorder to the socket (A15).
Power supply connections
Each indoor monitor requires its own power supply. Connect the GPE302-
type power pack's E1 plug to socket C1. Alternatively, use a central power
supply system (not supplied) and connect it to plug-in terminal C2.
For
a
central
power
supply
short- circuit-proof power supply units are authorised. Only allow
voltages/voltage types specifi ed in the "Technical Data" section,
with due regard for the required minimum current. Allowing other
voltages or voltage types will destroy the door intercom. Make sure that
the cables are correctly connected. Incorrect cable connection will also
destroy the door intercom.
Door opener
An electric door opener can be directly connected to the CVS door
intercom. Supply voltage: 12 V DC/max. 1 A.
Caution: do not use door openers requiring a higher operating current, as
this is likely to damage your CVS door intercom (and render your warranty
null and void).
Operation
Set the indoor monitor's ON/OFF switch A11 to ON. The LED A8 lights up
green and the B5 label on the outdoor monitor also lights up. The device
is now ready for use.
Use switch A12 on the indoor monitor to select the required ring tone
(1 to 3) or disable the ring tone (0 = OFF). If the ring tone is disabled, the
LED A8 will light up red. Use volume adjustment A10 to set the ring tone
volume independently of the general volume. Use volume adjustment A2
to set the general volume. On the outdoor monitor, set the volume using
volume adjustment B7.
If a visitor presses bell B4, the indoor monitor and (where fi tted) the
external bell or additional indoor monitor will ring. The visitor can then
speak into the outside monitor and be heard and seen by the person inside
the building. At this point, the person inside the building cannot be heard
by the person outside the building. When using the device for the fi rst time,
adjust the brightness and color (A13/A14).
Button A5 lights up when connection from the outdoor to the indoor
monitor is enabled. If no buttons are pressed, connection will stop
automatically after approx. 30 seconds.
If talk button A4 is pressed, the person inside the building can
failure
to
communicate with the person outside the building. During connection,
talk button A4 lights up. Press the door open button A7 to activate the
(optional) door opener.
Press button A4 or A5 again to stop communication. If no buttons are
pressed, communication will be automatically interrupted after approx.
2 minutes.
Outside monitoring
Surface-
Press button A5 to monitor the outside for 30 seconds.
Extending the system
Storey bell (optional)
Connect a standard button to connecting elements C9/C10. If this button
is pressed, the indoor monitor will ring with a preset ring tone which cannot
be adjusted.
External bell (optional)
The CAS external bell (item no. 087613) can be connected to connecting
elements C7/C8. The bell features volume adjustment with 3 volume
settings: OFF/quiet/loud.
Wireless bell (optional)
Terminals C5/C6 feature a fl oating relay contact (Normally Open). This
contact is closed when bell B4 is pressed. For example, connect the
GEV CGF 7079 wireless bell. Connect C5/C6 to contacts 1 + 3 on the
CGF 7079 wireless bell.
system,
only
GS-tested,
Additional video or audio indoor monitor (optional)
Connect an additional video or audio indoor monitor to connector C11.
Connection takes place via a cable featuring an RJ11 plug. The additional
monitor features connections for an outdoor bell or the CGF 7079 wireless
bell and video camera.
Troubleshooting - Practical tips
Problem
No ring tone, LED does not light up
No ring tone, LED lights up green
No ring tone, LED lights up red
Door opener does not work
Technical data
Indoor/additional monitor dimensions
Outdoor monitor
for 1 or 2 apartments
3 apartments
4 apartments
5 apartments
6 apartments
Power supply
Monitor
Camera lighting
Indoor monitor power supply (without door opener)
Standby mode
Operating mode
Connection
Distance from indoor to outdoor monitor
Distance from indoor monitor to additional monitor
Distance from indoor/additional monitor to bell
Power pack GPE302 (for each indoor monitor)
Input voltage
Output voltage
Rated current
Central power supply
Power supply
Rated current for 1 apartment
Rated current for 2 apartments
Rated current for 3 apartments
Rated current for 4 apartments
Rated current for 5 apartments
Rated current for 6 apartments
Additional indoor monitor
We reserve the right to make technical and visual modifi cations without prior notice.
Gutkes GmbH
Postfach 730 308 Fax: +49 (0)511 / 958 58 05
30552 Hannover
Internet: www.gev.de
Germany
E-Mail: service@gev.de
Connecting a handset (optional)
For more privacy, you can connect a handset to the indoor monitor.
Connect
the
handset
according
secure. Simply lift up the handset to communicate with the per-
son who has just pressed bell B4. The loudspeaker is automatically
disabled when the handset is lifted up. Press the talk button at any
time to conduct a conversation via the loudspeaker and microphone.
CE compliance information
Using the device near electromagnetic high frequency fi elds such as radio
systems, microwaves or mobile phones, or high electrostatic discharge,
can interfere with device operation. Should you encounter problems,
switch the power supply off and on again to restore operation.
Cause
Solution
Is the power pack connected?
Connect/check the power pack
Is the power pack faulty?
Faulty device?
Check the device
Is the cable connecting the indoor and
Check the cable
outdoor monitor incorrectly connected/faulty?
Is the ring tone volume adjustment set to 0?
Set ring tone adjustment to 1, 2 or 3
Wrong type of door opener?
Use a 12 V DC max. door opener
approx. W 160 x H 200 x D 46 mm
approx. W 81 x H 152 x D 47 mm
approx. W 81 x H 173 x D 47 mm
approx. W 81 x H 194 x D 47 mm
approx. W 81 x H 215 x D 47 mm
approx. W 81 x H 236 x D 47 mm
15 V
5.6 inch TFT type
min. 3 LUX located at < 50 cm
approx. 2 W
approx. 11 W
12 V
/max. 1 A
70 m max. (0.75 mm
2
)
2
20 m max. (0.45 mm
)
2
20 m max. (0.45 mm
)
230 V ~, 50 Hz
15 V
max. 1.5 A
15 V
max. 1.5 A
max. 1.6 A
max. 1.7 A
max. 1.8 A
max. 1.9 A
max. 2.0 A
+ 100 mA per device
to
additional
sheet
and

Publicité