GENERAL SETUP & OPERATION, ELECTRIC AMBIENT AIR PUMPS
MODELS BAC-10, BAC-17, BAC-20
STEP 1)
Install rubber feet on to the pump(s) as shown. Note: The
rubber feet are packaged separately for shipment.
STEP 2)
Check intake filter for excessive dirt and change if
necessary. Set compressor in a clean environment
away from hazardous dusts, mists, vapors, and
fumes.
STEP 3)
Use only constant flow Type-C respirators. Attach hose(s) and mask(s)
to system before turning the unit on, failure to do so will cause internal
motor damage.
Model BAC-10
STEP 5)
With the compressor running and respirators attached, loosen the relief valve
lock nut. Adjust outlet pressure to the setting recommended by the respira-
tor manufacturer.
DO NOT EXCEED 15psi output pressure (Models BAC-17 & BAC-20).
DO NOT EXCEED 12psi output pressure (Model BAC-10).
Turn the knob clockwise to increase pressure, counterclockwise to decrease
pressure and retighten the lock nut. The unit is now operational. Note: Do
not back the adjustment knob all the way out while unit is pressurized.
The loss of internal parts may occur.
netzerotools.com
SPECIAL SETUP - BAC-10 ONLY
The manifold assembly is packed separately in
the same box. Install manifold assembly on the
compressor prior to use. Thread the swivel fitting
onto the hex nipple and tighten securely.
STEP 4)
Assure that electric service amperage rating is in accordance with
electric motor specifications. Plug power cord into 120 VAC outlet
and turn switch "on". Note: If extension cords are used, they must
Model BAC-17
be gauged per NEC specifications.
& BAC-20