First, set the wooden plate on the bottom
surface of the niche in the cabinet. Then set
the appliance on the wooden plate. Make
certain that the body of the appliance is
positioned correctly.
Open the drawer and fasten the appliance
to the sides of the cabinet with 2 screws
and 2 spacers delivered with the appliance.
screws
Installation procedure with metal sheet
1. Peel off the double faced adhesive tape
protector from metal sheet
2. Stick metal sheet behind warming
drawer flange and make sure their
outside edges are aligned
3. Across the screw through hole of flange
and metal sheet
4. Fix the warming drawer in cabinet

2.3 Electrical Connection and Safety

WARNING: The electrical connection
of this appliance should be carried out
by an authorised service person or
qualified electrician, according to the
instructions in this guide and in compliance
with the current local regulations.
WARNING: THE APPLIANCE MUST
BE EARTHED.
WARNING:Before connecting the
appliance to the power supply, check
that the wires of your electric
installation have sufficient diameter to
supply power to the appliance normally. The
fuse for the installation should be 10 amps.
If during installation the glass of
warming drawer door and oven door is
not alligned, please insert spacers
(black metal sheets) between flange and
cabinet to adjust the installation position.
Thickness of each metal sheet is 1mm,
every one piece of metal sheet inserted will
let warming drawer move forward 1mm.
metal sheet (optional)
It is necessary to provide a bipolar cut-
off device in the power supply circuit,
where the opening of the contacts is
more than 3 mm.
The electric connection should be
done before the appliance is set in the
cabinet.
The drawer should be connected by
a (standard) power cord with three 1
mm2 couplers ( 1 single phase + 1 N +
ground) to the 220-240 V single phase
power supply via an electric circuit
corresponding to the standard CEI
60083 or complying with the installation
rules. The protective wire (green/
yellow) corresponds to ground on the
appliance and should be connected to
the ground of the installation.
In the case of a connection via an
electric outlet, the outlet should be
accessible after the installation of the
appliance.