ENGLISH
1. IR sensor lens
2. LED indicator
The LED indicator is inserted the front cover and can only
been seen when it is on.
3. Battery housing
The detector uses a CR123A (3V) battery
LED
In normal operating mode, the LED indicator blinks to indicate that signals are being transmitted in the following situations.
When movement is detected in flat battery conditions.
When the cover is opened and the micro tamper switch is actuated.
When movement detected if the tamper alarm condition persists.
When motion is detected in Test mode.
When the Test button is pressed in tampering conditions or if the battery of the detector is flat.
The LED does not blink if the tamper switch and the battery detector are in normal conditions and not in Test mode.
The LED blinks rapidly twice to confirm reception by the control unit.
Jumper for increasing sensitivity (JP3)
If the jumper is set to OFF (if the jumper connection is removed or positioned on only one pin), the
detection sensitivity is at normal level (default).
If the jumper is set to ON, the detection sensitivity of the detector is maximum.
Learning of the detector by the control unit
Extract the battery isolator to activate the battery,
The LED will blink for 30 seconds (the detector is being initialised). During initialisation, the detector will not be activated. It
is advisable not to generate any alarms during this time. Once the initialisation time has finished, the LED will switch off
and the detector is ready to start working.
Enable the control unit to run the device learning procedure. Refer to the control unit instruction manual for details.
Open the casing and press the Test button.
Refer to the instruction manual of the control unit to complete the learning process.
After having integrated the detector, set the control unit to "Walk Test" mode: keep the detector in the required position and
press the Test button to confirm that the concerned position is within the communication range of the control unit; see the
control unit instruction manual to complete the Walk Test.
Proceed with the installation after having ascertained that the detector is working in the desired position.
Test mode
The detector can be set to Test mode by pressing the Test button for a few seconds. In Test mode the sleep time will be deactivated
and the LED indicator will blink whenever movement is detected. Whenever the Test button is pressed, the detector transmits a test
signal to the control unit to test the wireless communication range and goes to Test mode for 3 minutes. It automatically exits Test
mode after 3 minutes and goes back to normal mode.
time that elapses between the transmission of a movement and the next transmission
SLEEP TIME
Installation
The detector was designed to be mounted on a flat surface, on a wall or in a corner using the fixing screws and the anchor bolts
provided.
If the detector is forcefully removed from the surface on which it is installed, the tamper switch pre-cut area will detach from the
detector remaining attached to the surface and the detector will generate an alarm.
Hole arrangements are provided on the base where the plastic is thinner and may be broken.
I. Release the cover from the base levering with a slot screwdriver in the housing provided for the purpose.
II. Perforate the appropriate hole arrangements on the inner side of the base.