The POA series of remote manifold boxes is designed to meet NIOSH requirements (adjustable regulator, pressure
gauge, safety relief valve, and respirator coupling(s) for a point-of-attachment when the work area is of consider-
able distance from the filtration source or main air supply. The POA series must be supplied with Grade-D air at
the required air pressure (psi) and volume (cfm).
Note: These units should be operated in the closed
position to prevent contamination and damage to
the internal components.
SPEciFicAtiOnS
Size
40.64 cm x 33.02 cm x 15.24 cm
Weight
Number of outlets depends on
Outlets
Maximum Air
Flow (cfm)
Maximum Inlet
Pressure
Maximum Outlet
Pressure
Relief Valve
Regulator
Adjustable, 0-125 psi (8.6 bar)
Note: All information in this manual applies to the wall mounted units as well.
Step 1)
Attach a 1/2" (13mm) incoming air line from the Grade-D compressed air source to the inlet fitting.
Step 2)
Attach desired respirators and lengths of hose to the quick connect outlet couplings.
Step 3)
Adjust the outlet pressure to the setting recommended by the respirator manufacturer. Turn the knob clockwise
to increase pressure, counterclockwise to decrease pressure.
• Make sure all personnel have egressed from the work area.
• Shut off air source to the Point-of-Attachment box.
• Remove air pressure from the Point-of-Attachment box by pulling out the relief valve ring.
• Disconnect airline hoses.
• Install dust caps, if applicable.
OvErviEw
16"L x 13"H x 6"D
10.5 lbs (4.8 kg)
model ordered
80 scfm@110 psi
2265 LPM@7.6 bar
150 psi (10.3 bar)
125 psi (8.6 bar)
125 psi (8.6 bar)

OPErAting PrOcEDurE

ShutDOwn
2

rEPLAcEMEnt PArtS

ITEM #
DESCRIPTION
1
INLET FITTING
2
REGULATOR
3
PRESSURE GAUGE
4
125 PSI RELIEF VALVE
5
HANSEN COUPLING
5A
SCHRADER COUPLING
6
HANSEN DUST CAP
6A
SCHRADER DUST CAP
PART #
QDH5PL8M
WL014
GA20160B
VR4125BR
QDH3SL6M
QDSSL6M
QDH3DCAP
QDSDCAP