INSTALLATION
INSPECT EQUIPMENT
File claim with shipper if equipment is
damaged.
INSTALLATION OF EVAPORATOR COILS
NOTE: Consult the furnace installation
instructions for any special requirements when
installing the coil to the furnace.
Upflow coil installation
The cased coil is designed to fit furnaces
of the same width.
1. Set coil in place on oil or gas furnace
supply air opening. Set coil in place on
electric furnace or air handler on the
return side.
2. Ensure coil is level for proper
condensate drainage. Do not tip coil
toward condensate drain.
3. When installing wider coil on narrow
furnace, use transition to fit the two
cabinets.
Page 7