Electrical connection must comply with national regulations.
Connection using multi-pole lockable wall socket in
compliance with IEC/EN 60309 and IEC/EN 60947 is
recommended in order to simplify electrical tests. If machines
are hard-wired, a multi-pole mains switch must be provided
on site. Switches with a contact gap of more than 3 mm can
be used. These include switches, fuses and contactors
(IEC/EN 60947). A wall socket or mains isolator must be
easily accessible after installation.
Reinstallation of the supply point, changes to the equipment
or checks on the protective conductor, including determination
of correct fuse rating, should only be performed by a properly
trained electrician.
If necessary, equipotential bonding with good galvanic contact
must be provided in accordance with all appropriate national
and local regulations.
Equi-potential
Sleeve with external thread
bonding
for washer and nut
(Option)
Fitting such as washers and nuts are only supplied with the
OS machine version.
If necessary, equipotential bonding with good galvanic
contact must be provided in accordance with all appropriate
national and local regulations.
Cold water
Min. water pressure/flow pressure
(soft water)
Max. water pressure/flow pressure
Max. throughput
Max. throughput (if hot or raw water supply is not available)
2 inlet hoses with ¾" threaded union (female
On-site connection thread
Length of inlet hose
Hourly water demand (average for 60°C cotton program)
determined at cold, hot and raw water connection
Add the hot water requirement to the cold water requirement,
if there is no hot water supply available.
If connected to hard water supply, subtract cold water (soft)
volume.
Hot water
Max. water temperature
(soft water)
Min. water pressure/flow pressure
Max. water pressure/flow pressure
Max. throughput
1 inlet hose with ¾" threaded union supplied.
On-site connection thread
Length of inlet hose
Hourly water demand (average for 60°C cotton program)
determined at cold, hot and raw water connection
If hot water is not available, connect hot water hose to cold
water valve!
Cold water
Min. water pressure/flow pressure
(hard water)
Max. water pressure/flow pressure
Max. throughput
(Option)
Optional retrofit kit: 2 inlet hoses with ¾" threaded union
(female)
On-site connection thread
Length of inlet hose
Hourly water demand (average for 60° cotton program)
determined at cold, hot and hard water connection
Technical datasheet: PW 6207 EL (electric)
Date: 03.2015
All manuals and user guides at all-guides.com
3/8 x 1 3/8"
10 × 35 mm
M 10
14.5 psi
100 kPa
145 psi
1000 kPa
6.9 gal/min
26 l/min
11.1 gal/min
42 l/min
Inch
¾" garden hose
thread, male
59 1/16"
1500 mm
Approx. 30.6
Approx. 116 l/h
gal/h
158°F
70°C
14.5 psi
100 kPa
145 psi
1000 kPa
4.2 gal/min
16 l/min
Inch
¾" garden hose
thread, male
59 1/16"
1500 mm
Approx. 31.4
Approx. 119 l/h
gal/h
14.5 psi
100 kPa
145 psi
1000 kPa
8.5 gal/min
32 l/min
Inch
¾" garden hose
thread, male
59 1/16"
1500 mm
Approx.19
Approx. 72 l/h
gal/h
Page: 12