PROPANE CONVERSION INSTRUCTIONS
WARNING
Explosion Hazard
Death or serious injury can result from failure to follow
these instructions.
• Replace all parts and panels before operating.
natural gas. To use propane gas, the regulator and burner
WARNING
Do not operate the cooktop when using
result in serious injury.
packaged with the unit.
TOOLS REQUIRED:
(blade approximately
or 7mm
3/32" across)
To adjust your cooktop for use with propane gas, follow these
instructions:
1. Disconnect all electrical power, at the main circuit breaker or
fuse box.
CONVERTING THE PRESSURE REGULATOR
1. Use an adjustable wrench to unscrew the hex-nut cap from
the pressure regulator.
2. Turn the plastic cap 1/4 turn to disassemble.
the tabs of the plastic cap with the slots of the hex-nut cap.
Insert cap and rotate 1/4 turn to reassemble. The letters
4. Screw the hex-nut cap back onto the pressure regulator.
Rotate cap counter-
clockwise to loosen
NAT
PROPANE
CONVERTING THE COOKTOP BURNERS
Burner cap
Burner cap
through this
Burner head
opening
Base
Multi-ring
Round burner
(on some models)
opening in the base.
NOTICE:
appliance for future use.
from the bracket attached to
LR
C
the regulator. The top surface
LF
placement of the propane
C1
C2
C1
95
Denotes 0.95mm Orifice size opening
Denotes LP (Propane)
III
BURNER OUTPUT RATINGS: BTU/HR
Propane Gas 10" W.C.P.
ORIFICE
BTU RATE
SIZE (mm)
BURNER
LF
9,500
LR
9,500
C
18,000
C1
N/A
0.686
C1
N/A
0.686
C1
N/A
0.686
C2
N/A
RR
5,000
RF
15,000
D.
in their precise locations.
screwed into the gas injets.
E.
these instructions, and replace onto the regulator for
Burner cap
Burner head
Base
RR
RF
C1
CHECK SURFACE BURNERS
Push and turn a knob to the LITE position. A clicking sound
indicates proper operation of the ignition system. When lighting
from only the one selected. Once air is purged from the supply
line, burner should light within 4 seconds. After burner lights,
MARKING
rotate the knob out of the LITE position. Try each burner in
0.91
91L
0.91
91L
Quality of Flames
69L
should look like (A) or (B).
69L
69L
0.41
41L
0.66
66L
1.15
115L
show signs of an orange tint when well heated or signs of
PROPANE CONVERSION INSTRUCTIONS
(A) Soft blue flames—
Normal for natural gas
(B) Yellow tips on
outer cones—
Normal for propane gas
31-2001100 Rev. 0 04-22 GEA
PGP9036, CGP9536

Publicité

loading

Sommaire des Matières pour GE PGP9036

  • Page 1 Base Multi-ring Round burner (on some models) opening in the base. NOTICE: appliance for future use. from the bracket attached to the regulator. The top surface placement of the propane PROPANE CONVERSION INSTRUCTIONS 31-2001100 Rev. 0 04-22 GEA PGP9036, CGP9536...
  • Page 2 Turn clockwise as far as possible while maintaining a ADDITIONAL INFORMATION slowly turn adjustment screw PGP9036 - BURNER OUTPUT RATINGS: BTU/HR Center adjustment screw for all burners except the NG (Natural) Gas 5” W.C.P. exists for each burner.
  • Page 3 Plusieurs anneaux Brûleur rond (certains modèles) B. À l’aide d’un tournevis à douille 7 mm ou 9/32 po, retirez les AVIS : tableau et à l’illustration pour INSTRUCTIONS POUR LA CONVERSION AU PROPANE 31-2001100 Rev. 0 04-22 GEA PGP9036, CGP9536...
  • Page 4 (LP). AVIS : Brûleurs ronds RENSEIGNEMENTS SUPPLÉMENTAIRES PGP9036 - PUISSANCE CALORIFIQUE DES BRÛLEURS : BTU/H instable, tournez lentement la vis de Gaz nature (NG) 5 po de colonne d’eau TAUX BTU DIA. ORIFICE (mm) MARQUAGE BRÛLEUR...
  • Page 5 • • Quemadores o 7mm aproximadamente 3/32” de Cabezal del Cabezal del de Esta Abertura Base Base Anillo múltiples Base du brûleur (en algunos modelos) AVISO: propano (LP). INSTRUCCIONES DE CONVERSIÓN A PROPANO 31-2001100 Rev. 0 04-22 GEA PGP9036, CGP9536...
  • Page 6 Quemadores Redondos C. Retire la perilla e inserte un INFORMACIÓN ADICIONAL posible, mientras mantiene una llama PGP9036 - CALIFICACIONES DE POTENCIA DE LOS QUEMADORES BTU/HR Gas NG (Natural) 5” W.C.P. (Presión de Columna de Agua) PROMEDIO DE TAMAÑO DEL ORI-...

Ce manuel est également adapté pour:

Cgp9536