Kathrein Power Saving
If an EXE 159 is operated alone or together with other multi-switches that bear the Kathrein
Power Saving logo, Kathrein Power Saving can be activated by setting the stand-by switch
to "ON". If a receiver in the cascade is switched on, the LNB is powered through the end
multi-switch.
Multi-switches without Kathrein Power Saving do not give signalling to the
end multi-switch. The stand-by switch must be set to "OFF" for permanent
powering of the LNB.
Type
Product type
VWS 2551
Amplifi ers
EBX 2520
Two-way splitter
EAX 2512
Two-way tap
VWS 2500
Amplifi ers
PIN code protection
The multi-switch is protected by a PIN code in order to prevent the set userband from be-
ing used/disturbed by another subscriber. This should be specifi ed in the receiver settings.
A fi xed PIN has been assigned to each userband.
UB 1
Frequency
974
(MHz)
PIN
151
All manuals and user guides at all-guides.com
Kathrein Power Saving
Can be used without restriction
Note: If the terrestrial frequency
range is used, the VWS (amplifi er)
must be locally powered.
Can be used without restriction if
each trunk has been terminated
with a Kathrein Power Saving-
capable end multi-switch.
Not compatible with Kathrein Power
Not compatible with Kathrein Power
UB 2
UB 3
UB 4
1,076
1,178
1,280
052
133
124
4 / 8
Saving
Saving
UB 5
UB 6
UB 7
1,382
1,484
1,586
205
196
187
Switch position
ON
ON
OFF
OFF
UB 8
UB 9
1,688
1,790
178
099

Publicité