Télécharger Imprimer la page

Honeywell 0061511 Manuel De L'utilisateur page 17

Publicité

Les langues disponibles

Les langues disponibles

3.5 SERVICE AIR FILTER
The engine will not run properly and may be damaged if using a
dirty air filter. Clean or replace the air filter paper filter once a year.
Clean or replace more often if operating under dusty conditions
(Figure 15).
To clean or replace paper air filter:
1. Remove air filter cover and remove paper filter.
2. Clean paper filter by tapping it gently on a solid surface. If the
filter is too dirty, replace it with a new one. Dispose of the old
filter properly. The air filter part number is 0G84420151.
3. Clean air filter cover, then insert new paper filter into the base
of the air filter. Re-install air filter cover.
To order a new air filter, please contact the nearest authorized
service center at 1-855-GEN-INFO.
Figure 15 - Air Filter
KNOB TO
OPEN AIR BOX
3.5.1 CLEAN SPARK ARRESTOR SCREEN (CARB
MODELS)
The engine exhaust muffler has a spark arrestor screen. Inspect
and clean the screen at least once each year (Figure 16). If unit is
used regularly, inspect and clean more often.

If using the generator on any forest-covered,
brush-covered or grass-covered unimproved
land, it must be equipped with a spark arrestor.
The spark arrestor must be maintained in good
condition by the owner/operator.
NOTE:
Clean and inspect the spark arrestor when the engine is at ambient
temperature as follows:
1. Remove the spark arrestor screen from the muffler by
loosening the clamp and removing the screw.
2. Inspect screen and replace if torn, perforated or otherwise
damaged. DO NOT USE a defective screen. If screen is not
damaged, clean it with commercial solvent.
3. Replace the spark arrestor and secure with the clamp and
screw.
To order a new air filter or spark arrestor screen, please contact
the nearest authorized service center at 1-800-333-1322.
Figure 16 – Spark Arrestor Screen
3.6 VALVE CLEARANCE
• Intake — 0.15 ± 0.02mm (cold), (0.006" ± 0.0008" inches)
• Exhaust — 0.20 ± 0.02mm (cold) (0.008" ± 0.0008" inches)
After the first 50 hours of operation, check the valve clearance
in the engine and adjust if necessary.
Important: If feeling uncomfortable about doing this procedure or
the proper tools are not available, please take the generator to the
nearest service center to have the valve clearance adjusted. This is
a very important step to ensure longest life for the engine.
Maintenance
NOTE:
15
15

Publicité

loading