Dgp 8-32 zones dans coffret chargeur 3 a

Publicité

Les langues disponibles

Les langues disponibles

3. Available Aux/Battery current based on backup
Time (h)
Approval
Grade
Discharge
12
EN 1&2
60
EN 3&4
Nfa2p
36
ΙΙ
Nfa2p
72
ΙΙΙ
VdS
30
B
VdS
60
C
4. General Feature Specifications
End of line resistor (standard)
Standard on board output
Housing Dimensions
Environmental
5. Fuses
F4
Auxiliary power & siren
Mains fuse *
* Mains Fuse is part of the mains terminal block.
!
WARNING! Before removing the mains fuse, mains power must be disconnected (see page 4)!
All manuals and user guides at all-guides.com
Charge
Output
72
Aux
Battery
24
Aux
Battery
30
Aux
Battery
30
Aux
Battery
24
Aux
Battery
24
Aux
Battery
4.7 kΩ 5% 0.25 W (2.2 kΩ or 10 kΩ)
Ext.siren (J13 - S+/S-)
ATS1203: 370 x 475 x 160mm
ATS1204: 460 x 475 x 160mm
Operating temperature
Humidity
IP protection grade
F2 A, 20x5
F5
F630 mA, 20x5
8
Current (mA)
Battery capacity
7.2Ah
18Ah
25Ah
490
1300
1800
2235
1425
925
40
220
330
2685
2500
2395
110
360
550
2615
2350
2200
20
150
230
2700
2600
2500
150
500
700
2575
2225
2025
40
220
330
2685
2500
2395
Electronic output
Rating: 1 A at 13.8 VDC
Colour
0° to + 50 °C (certified +5° +40°C)
95% non condensing
IP30
Battery
36Ah
50Ah
1800
1800
925
925
500
550
2225
2175
850
1000
1875
1725
380
580
2345
2100
1050
1100
1675
1625
500
550
2225
2175
Beige
F3 A, 20x5