PRECAUTIONS FOR SAFETY
• Do not install, repair, open or remove the cover. It may expose
you to dangerous voltages. Ask the dealer or the specialist to
do this.
• Turning off the power supply will not prevent potential electric shock.
DANGER
• The appliance shall be installed in accordance with national
wiring regulation.
• Means for disconnection from the supply having a contact
separation of at least 3 mm in all poles must be incorporated in
the fi xed wiring.
• Do not expose your body directly to cool air for a long time.
• Do not insert your fi nger or any article into the air inlet/outlet.
WARNING
• When an abnormality (burning smell, etc.) occurs, stop the air
conditioner and disconnect the power supply or turn off the
breaker.
• Do not wash the unit with water. It may cause an electric shock.
• Do not use this air conditioner for other purposes such as
preserving food, breeding animal, etc.
• Do not step or put anything on the indoor/outdoor unit. It may
cause an injury or damage the unit.
• Do not touch aluminium fi n because it may cause an injury.
CAUTION
• Before cleaning the unit, turn off the main switch or the circuit
breaker.
• When the unit won't be used for a long time, turn off the main
switch or the circuit breaker.
• It is recommended that maintenance be performed by a
specialist when the unit has been operated for a long time.
INDOOR UNIT DISPLAY
1
Models: RAS-13SKP-E
1 Hi POWER (Green)
4
5
2 FILTER (Orange)
3 FAN-ONLY (Orange)
Hi POWER
FILTER
FAN-ONLY
TIMER
OPERATION
4 TIMER (Yellow)
5 OPERATION (Green)
1
2
3
6 RESET button
RESET
6
Models: RAS-07, 10SKP-E
1 OPERATION (Green)
CLEANING
2 TIMER/CLEANING (Yellow)
RESET
TIMER
OPERATION
3 RESET button
3
2
1
2
PREPARATION BEFORE USE
Preparing Filters
1. Open the air inlet grille and remove the air fi lters.
2. Attach the fi lters. (see detail in the accessory sheet).
Loading Batteries
1. Remove the battery cover.
2. Insert 2 new batteries (AAA type)
following the (+) and (–) positions.
Clock Setup
1. Push CLOCK
by tip of the pencil.
2. Press
ON
or
OFF
: adjust the time.
3. Press
: Set the time.
SET
Remote Control Reset
1. Remove the battery.
2. Press
.
3. Insert the battery.
3
AIRFLOW DIRECTION
FIX
1
Press
: Move the louver in the
desired vertical direction.
SWING
2
Press
: Swing the air
automatically and press again to stop.
For horizontal direction, adjust
3
manually.
Note:
• Do not move the louver manually by others.
• The louver may automation positioning by come operation mode.
4
REMOTE CONTROL
1 Infrared signal emitter
2 Start/Stop button
3 Mode select button (MODE)
4 Temperature button (TEMP)
5 Fan speed button (FAN)
6 Swing louver button (SWING)
7 Set louver button (FIX)
8 On timer button (ON)
9 Off timer button (OFF)
! Sleep timer button (SLEEP)
" Setup button (SET)
# Clear button (CLR)
$ Memory and Preset button (PRESET)
% One Touch button (ONE-TOUCH)
& High power button (Hi-POWER)
( Economy button (ECO)
) Quiet button (QUIET)
~ Comfort sleep button (COMFORT SLEEP)
+ Filter reset button (FILTER)
, Clock reset button (CLOCK)
- Check button (CHK)
ONE-TOUCH
5
Press the "ONE-TOUCH" button for fully automated operation that is customised
to the typical consumer preferences in your region of the world. The customised
settings control temperature air fl ow strength, air fl ow direction and other
settings to provide you alternate contact with "ONE-TOUCH" of the button. If
you prefer other settings you can select from the many other operating functions
of your Toshiba unit.
ONE-TOUCH
Press
: Start the operation.
6
AUTOMATIC OPERATION
To automatically select cooling, or fan only operation
MODE
1. Press
: Select A.
TEMP
2. Press
: Set the desired temperature.
7
COOLING / FAN ONLY OPERATION
MODE
1. Press
: Select Cool
, or Fan only
TEMP
2. Press
: Set the desired temperature.
Cooling: Min. 17
o
C, Fan Only: No temperature indication
FAN
3. Press
: Select AUTO, LOW , LOW+
HIGH
.
8
DRY OPERATION
For dehumidifi cation, a moderate cooling performance is controlled
automatically.
MODE
1. Press
: Select Dry
.
TEMP
2. Press
: Set the desired temperature.
Hi-POWER OPERATION
9
To automatically control room temperature and airfl ow for faster cooling
operation (except in DRY and FAN ONLY mode)
Hi-POWER
Press
: Start and stop the operation.
10
ECO OPERATION
To automatically control room to save energy (except in DRY and FAN ONLY
mode)
ECO
Press
: Start and stop the operation.
Note: Cooling operation; the set temperature will increase automatically 1
degree/hour for 2 hours (maximum 2 degrees increase).
1
PRESET
FAN
$
5
TEMP
4
ONE-TOUCH
MODE
3
%
~
2
COMFORT
QUIET
PURE
SLEEP
)
&
SWING
FIX
Hi-POWER ECO
(
6
7
#
TIMER
CLR
8
9
ON
OFF
!
"
SLEEP
SET
-
CHK
FILTER
CLOCK
,
+
.
, MED
, MED+
, or

Publicité

loading

Ce manuel est également adapté pour:

Ras-07s2a serieRas-13skp serieRas-13s2a serie