Télécharger Imprimer la page

Kuppersbusch EGE3710.1 Mode D'emploi page 25

Publicité

Les langues disponibles
  • FR

Les langues disponibles

 Not to install the hob to the top of a not ventilated oven or a dishwasher.
 To guarantee under the bottom of the hob casing a space of 20 mm to ensure a good air
circulation of the electronic device.
 If a drawer is placed under the work, avoid to put into this drawer flammable objects (for
example: sprays) or not heat-resistant objects.
 Materials which are often used to make worktops expand on contact with water. To protect
the cut out edge, apply a coat of varnish or special sealant. Particular care must be given
to applying the adhesive joint supplied with the hob to prevent any leakage into the
supporting furniture. This gasket guaranties a correct seal when used in conjunction with
smooth work top surfaces.
 The safety gap between the hob and the cooker hood placed above must respect the
indications of the hood manufacturer. In case of absence of instructions respect a distance
minimum of 760 mm.
 The connection cord should not be subjected, after building-in, to any mechanical
constraint (for instance constraint given by a drawer installed below).
ELECTRICAL CONNECTION
 The installation of this appliance and the connection to the electrical network should be
entrusted only to an electrician perfectly to the fact of the normative regulations and which
respects them scrupulously.
 Protection against the parts under tension must be ensured after the building-in.
 The data of connection necessary are on the stickers place on the hob casing near the
connection box.
 The connection to the main must be made using an earthed plug or via an omnipolar
circuit breaking device with a contact opening of at least 3 mm.
 The electrical circuit must be separated from the network by adapted devices, for example:
circuit breakers, fuses or contactors.
 If the appliance is not fitted with an accessible plug, disconnecting means must be
incorporated in the fixed installation, in accordance with the installation regulations.
 The inlet hose must be positioned so that it does not touch any of the hot parts of the hob
or oven.
Caution!
This appliance must only be connected to a network 230 V~ 50/60 Hz.
Always connect the earth wire.
Respect the connection diagram.
The connection box is located underneath at the back of the hob casing. To open the cover, use
a medium screwdriver. Place it in the slits and open the cover. Attach the earth to the terminal
"earth", the neutral N to terminal N, the Phase L1 to one of the terminals L.
Mains
230V~ 50/60Hz
* calculated with the simultaneous factor following the standard EN 60 335-2-6/1990
Caution!
Ensure that the cables are correctly inserted and tightly screwed down.
We cannot be held responsible for any incident resulting from incorrect connection or
which could arise from the use of an appliance which has not been earthed or has been
Connection
Cable diameter
1 Phase + N
3 x 1.5 mm²
equipped with a faulty earth connection.
Cable
H 05 VV - F
H 05 RR - F
25
Protection calibre
16 A *

Publicité

loading

Ce manuel est également adapté pour:

Ege3710.1ed