APPLIANCE
Before install a stove in a room, select the right stove to be able to heat the room.
Please check the STOVES' Heating area in the Chapter of STOVE FEATURE.
COMPLETE THE STOVE BEFORE INSTALLATION
GENERAL INFORMATION
The stove must be connected to a chimney that is approved for solid fuels. The chimney must
have a diameter of 80 mm since the beginning until the end of the installation. The flue
system is based on negative pressure in the combustion chamber and a slight overpressure on
the flue gas outlet. It is therefore important that the flue gas connection is fitted correctly and
is airtight.
Only use heat resistant sealing materials, as well as the relevant sealing bands, heat
resistant silicon and mineral wool.
Only authorized technical personnel must carry out assembly work.
In addition, you must ensure that the flue tube does not project into the free cross section of the
chimney.
NOTE: Please follow the regionally valid building regulations. Contact your master
chimney sweep for information on this.
Ensure that outlet routes to the chimney are not too long.
Avoid too many changes of direction for the flue gas flow to the chimney. (e.g., too many
corners and bends).
Where you cannot connect directly to the chimney, if possible, use a connection piece with
cleaning opening.
For optimum efficiency please use the type of connector we recommend.
FLOOR PROTECTION
For flammable floor surfaces (wood, carpet, etc.) a glass, steel plate or ceramic underlay is
required.
48