SERVICE PROCEDURES
To avoid serious injury or death, read all
IMPORTANT SAFETY INFORMATION
at the front of this manual.
Removing the Top Panel
WARNING! Completely shut down and unplug oven
before proceeding. Refer to "Shutdown" procedure.
1. Completely shut down and unplug the oven. Refer to the
"Shutdown" procedure in the OPERATION section.
2. Remove two (2) 1/4" hex screws that secure the top panel
to the rear frame.
3. Slide the top panel toward the rear of the oven to release
the front and side tabs, then lift panel off the oven.
Removing the Element Access Panel
1. Completely shut down and unplug the oven. Refer to the
"Shutdown" procedure in the OPERATION section.
2. Remove two (2) 1/4" hex screws that secure the element
access panel to the rear frame.
3. Tilt the panel back, and lift out of the slot on the oven frame.
Top Cover
Side Tab
(1 of 4)
Hex
Screw
IMPORTANT NOTE
Many of the service procedures in this section require removal
of insulation to access the parts. All illustrations are shown with
insulation removed for clarity.
Front Tab
(1 of 3)
Tab Slot
Hex
Screw
20
English
Slot
Element
Access Panel
OVMISAM-0522