6. INSTALLAZIONE
Modulo di controllo Slave
RISCALDATORE ACQUA
Superior
L
N
PE
PE
+24V
GND 0-10V
Master
IN
230V
CALORE 0-10V
L
N
PE
IN
230V
INPUT
Entrée
1
0-10
0-10
24VAC
24VAC
24VAC
VDC
GND
VDC
GND
1
1
2
2
1
24V
GND
24V
GND
24V
GND
23 24
23 24
23 24
25 26
25 26
1
1
2
1
2
24VAC
24VAC
0-10V
24VAC
24VAC
0-10V
24VAC
24VAC
MIX. POINT / OUTDOOR
POWER SUPPLY
MIX. POINT / OUTDOOR
POWER SUPPLY
Alimentation
Vanne/ Groupe Exterieur DX
Vanne/ Groupe Exterieur DX
Alimentation
Alimentation
UNIT DX
MIX POINT
UNIT DX
MIX POINT
MIX POINT
vanne
vanne
vanne
HEATER/
HEATER/
VENT-EXT
VENT-INT
VENT-EXT
PREHEATER
24VAC
24VAC
PREHEATER
24VAC
24VAC
REC/BYP
24VAC
REC/BYP
POSTHEATER
GND GND
RPM
RPM
COOL/PUMP
COOL/PUMP
GND
PWM
GND
1
1
GND
PWM
GND
GND
1
1
PWM
GND
1
PWM
GND
~
~
2
~
~
2
0-10V
~
GND
+SSR -SSR
~
~
~
2
0-10V GND
(TC)
~
~
2
0-10V
GND
(TC)
0-10V GND
0-10V
0-10V
GND
GND
13 14
15
16 17 18 19 20 21 22 23 24
25 26 27 28 29
30
31
32
25 26 27 28 29
30
31
32
33
9
8
FUSE
FUSE
7
(VENT-EXT)
(VENT-INT)
6
5
4
FUSE
FUSE
(PCB)
(PERIPHERY)
3
2
83
82
81 80 79 78 77 76 75 74 73
72 71
68 67 66 65 64 63 62 61 60 59 58 57 56 55 54 53 52 51
72 71
70 69
68 67 66 65 64 63 62 61 60 59 58 57 56 55 54 53 52 51
70 69
1
LO
N
LO
L
LO
L
LO
N
LO
N
N
L
ALARM
ALARM
RUN
RUN
COOL/HEAT
COOL/HEAT
ALARM
ERROR
DEFROST EXTERNAL
N
ERROR
DEFROST EXTERNAL
230VAC
230VAC
230VAC
230VAC
230VAC
230VAC
HEATER
OUTPUT
HEAT PUMP
HEATER
HEATER
OUTPUT
HEAT PUMP
HEAT PUMP
HEAT PUMP
W. PUMP
PIR
FLAP-INT
FLAP-EXT
W. PUMP
230VAC
EXTERNAL
CONTACT
EXTERNAL
POMPE
WATER
CONTROL
CONTROL
EXTERNE
DE CIRCULATION
PUMP CONTROL
OUTPUT
OUTPUT
72 71
72 71
72 71
77 78
76 75
63 64
6
6
6
DX = ON/OFF
DX = ON/OFF
DX = ON/OFF
DX = ON/OFF
7
DX = ON/OFF
DX = ON/OFF
7
5
OUTLET
(Sortie pour unité
(Sortie pour unité
(Sortie pour unité
(Output for outdoor unit)
(Output for outdoor unit)
Registre
Commande
Commande
exterieure)
exterieure)
exterieure)
Air Rejeté
á distance
á distance
68 67
70 69
70 69
68 67
70 69
66 65
66 65
!
!
DX GENERAL ERROR
DX DEFROST
DX GENERAL ERROR
DX DEFROST
8
9
8
8
9
(settable)
(settable)
(settable)
(settable)
PRESENCE
PRESENCE
CAPTEUR
CAPTEUR
Superior
Superior
L
N
L
PE
N
PE
PE
PE
+24V
Master
Master
IN
IN
230V
230V
AMBIENTE
Fu
L
N
PE
N
L
N
PE
2A
IN
IN
OUT
230V
230V
8
2
3
Control panel
Control panel
boitier de commande
boitier de commande
0-10
VDC
GND
24
23
22
2
20
19
25 26
49 50
49 50
EXT. SENSOR
2
EXT. SENSOR
3
3
Capteur Externe.
0-10V
Capteur Externe.
MIX. POINT / OUTDOOR
(two-wire shielded cable)
(two-wire shielded cable)
Câble deux fils blindé
Câble deux fils blindé
Vanne/ Groupe Exterieur DX
UNIT DX
HEATER/
PREHEATER
T-WATER T-WATER T-ROOM
POSTHEATER
24VAC
REC/BYP
POSTHEATER
T-WATER T-WATER T-ROOM
T-EXT-1 T-EXT-2 T-EXT-3 T-INT-1 T-INT-2
T-EXT-1 T-EXT-2 T-EXT-3 T-INT-1 T-INT-2
COOL/PUMP
T-EXT-1 T-EXT-2 T-EXT-3 T-INT-1 T-INT-2
1
-OUT
+SSR -SSR
2
~
~
2
0-10V
GND
+SSR -SSR
-OUT
0-10V GND
0-10V
GND
33
25 26 27 28 29
34
35 36 37 38 39 40 41 42 43
30
31
32
33
34
35 36 37 38 39 40 41 42 43
44 45 46 47 48 49 50
34
35 36 37 38 39 40 41 42 43
44 45 46 47 48 49 50
SWO
SWO
DATA
DATA
72 71
68 67 66 65 64 63 62 61 60 59 58 57 56 55 54 53 52 51
70 69
1
1
PRESENCE
PRESENCE
RUN
COOL/HEAT
REC ERR
REC ERR
ERROR
DEFROST EXTERNAL
FIRE
BOOST
FIRE
BOOST
15VAC
15VAC
SENSOR
SENSOR
OUTPUT
HEAT PUMP
CO2/RH/EXT
ON/OFF
HEAT PUMP
ON/OFF
CO2/RH/EXT
ON/OFF
PIR
PIR
CONTACT
EXTERNAL
CONTACT
CONTACT
CONTACT
FIRE
CONTACT
FIRE
CONTROL
EXTERNE
EXTERNE
OUTPUT
INCENDIE
INCENDIE
INCENDIE
ON/OFF
BOOST
BOOST
ON/OFF
ON/OFF
3
4
5
6
7
8
63 64
62 61
62 61
63 64
57 58
57 58
BOOST
BOOST
4
5
6
7
11
12
13
11
11
12
13
Commande
CMSI
CMSI
á distance
68 67
66 65
defrost
defrost
!
defrost
2VV. Dal 1995, creiamo soluzioni innovative per voi e per il vostro business.
DX GENERAL ERROR
DX DEFROST
10
10
10
9
(settable)
(settable)
PRESENCE
CAPTEUR
Fu
Fu
N
N
+24V
GND 0-10V
GND 0-10V
2A
2A
OUT
OUT
GTC
GTC
ou
ou
or
or
Control panel
boitier de commande
ModBUS RTU via
ModBUS RTU via
Rs485
Rs485
49 50
EXT. SENSOR
3
Capteur Externe.
(two-wire shielded cable)
Câble deux fils blindé
J1/J2
J1/J2
J1/J2
T-WATER T-WATER T-ROOM
-IN
-OUT
-IN
-IN
FILTER
FILTER
9
9
10
10
JP1
JP1
INT
INT
LED1
LED1
44 45 46 47 48 49 50
SWO
DATA
1
2
2
2
PRESENCE
IN GND
IN GND
IN GND
REC ERR
FIRE
BOOST
15VAC
SENSOR
CO2/RH/EXT
PIR
FIRE
CONTACT
CONTACT
CONTACT
ERROR
ERROR
ERROR
CONTACT
ERREUR
CONTACT
ERREUR
CONTACT
ERREUR
BOOST
9
10
11
59 60
59 60
62 61
59 60
57 58
BOOST
7
!
!
!
14
14
12
14
13
CMSI
CO
CO
/ RH/VOC
/ RH/VOC
CAPTEUR 0-10V
CAPTEUR 0-10V
SENSOR
SENSOR
CO
/ RH/VOC
2
2
2
16
15
16
15
EXTERNAL
15
EXTERNAL
EXTERNAL
51 52
51 52
53 54
53 54
53 54
1
2
2
1
2
GTC
ou
or
ModBUS RTU via
Rs485
1
Sensore uscita LPHW (incluso nella fornitura)
2
Segnale da unità master
3
Allarme riscaldatore (NC)
4
Controllo esterno (ingresso, NA/NC)
5
Termostato ambiente (ingresso, NA/NC)
6
Contatto PORTA (ingresso, NA/NC)
FILTER
9
7
Unità master Modbus RTU
10
JP1
INT
LED1
8
Controllo valvola acqua (0-10V)
CAPTEUR 0-10V
SENSOR
16
51 52
1