Operating Manual - smoke unit Typ fog-smoker
5. FOGGING FLUID
5.1. General
The following points are absolutely to be noticed:
Attention
• Use only manufacturer approved fogging fluid "Drain-Fog" and "Fire-Drill"!
• The use of third party fluids will void the warranty on parts which come directly in
contact with the fluid.
• Do not swallow fogging fluid and keep it away from children!
5.2. Replacing the container
• Push back the locking sleeve (G) and remove the plug-in grommet (F).
• Remove the empty container (J) from its bracket.
• Remove the container cap (H) from the empty container and place it onto the full container.
• Place the full container in its bracket.
• Snap the plug-in grommet into the hose coupling again.
6. OPERATING THE FOG-SMOKER 2F
6.1. Choosing the location
The location of the smoke unit must:
• be free of vibrations,
• be not inflammable,
• be sufficiently supplied with fresh air,
• have an ambient temperature between 5°C and 45°C (41°F to 113°F)
• and a relative humidity of max. 80%.
6.2. Start
• Please follow the instructions on operation of emergency power sets under section 3.3.!
• Connect the mains plug (L) with a grounded socket (230V/50Hz).
• A dot (I2) appears at the right bottom of the keypad display (I1).
• Press the ON button (I4) to switch on the unit. The fan turbine now runs idle.
• After a heating phase of approx. 7 min the smoke unit is ready for operation. The green
Ready-LEDs (I3) are on.
• You must adjust the air and fog quantities in 10 levels by pressing the + and – buttons (I1).
6.3. Shutting off
• Allow the unit to cool after the fogging procedure with a selected fog quantity of "0" for approx.
5 min. The forced ventilation of the unit (air quantity "0") is sufficient for that purpose.
• Press the OFF button (I5) to switch off the unit.
• Then disconnect the mains plug.
14
I1
I2
00 00.
BEREIT
READY
LUFT/AIR
NEBEL/FOG
+ +
+ +
ON
-
-
OFF
I3
I4
I5