If an indirect refrigerating circuit is being used, the secondary circuit must be
checked for the presence of refrigerant.
Marking to the equipment continues to be visible and legible. Markings and
signs that are illegible must be corrected.
Refrigeration pipe or components are installed in a position where they
are unlikely to be exposed to any substance which may corrode refrigerant
containing components, unless the components are constructed of materials
which are inherently resistant to being corroded or are suitably protected
against being corroded.
Checks to Electrical Devices
Repair and maintenance to electrical components must include initial safety
checks and component inspection procedures. If a fault exists that could
compromise safety, then no electrical supply must be connected to the circuit until
it is satisfactorily dealt with. If the fault cannot be corrected immediately but it is
necessary to continue operation, an adequate temporary solution must be used.
This must be reported to the owner of the equipment, so all parties are advised.
Initial safety checks must include:
Those capacitors are discharged: this must be done in a safe manner to avoid
possibility of sparking.
That no live electrical components or wiring are exposed while charging,
recovering or purging the system.
That there is continuity of earth bonding.

Connection to the power supply

Caution: Risk of electric shock. Do not open.
This appliance is supplied with a moulded 3 pin mains plug for your safety.
The value of the fuse fitted is marked on the pin face of the plug. Should the
fuse need replacing, ensure the substitute is of the correct rating, approved to
BS1362 and ASTA
The fuse cover is removable with a small plain slot screwdriver. Ensure the fuse
cover is replaced before attempting to connect the plug to an electrical outlet.
If the cover is missing, a replacement must be obtained or the plug replaced
with a suitable type.
If a replacement plug is to be fitted this must be carried out by a qualified
electrician.
The damaged or incomplete plug, when cut from the cable should be disabled
to prevent connection to a live electrical outlet.
This appliance is Class I and is designed for connection to a power supply
matching that detailed on the rating label and compatible with the plug fitted.
If an extension lead is required, use an approved and compatible lead rated for
this appliance. Follow all the instructions supplied with the extension lead.
Class I
:Products with this symbol must have metal parts connected to
electrical earth by an earth conductor. The basic requirement is that no single
failure can result in dangerous voltage becoming exposed so that it might
cause electric shock.
Important: If using an extension lead, follow the instructions that came with your
lead regarding maximum load while cable is wound. If in doubt, ensure that the
entire cable is unwound. Using a coiled extension lead will generate heat which
could melt the lead and cause a fire.