ELECTRICAL CONNECTION

• The installation of this appliance and the connection to the electrical system should be
entrusted only to a qualified electrician.
• Protection against the parts under tension must be ensured after instalation
• The data of connection necessary are on the stickers place on the hob casing near the
connection box.
• The connection to the mains must be made using an earthed plug or via an omnipolar
circuit breaking device with a contact opening of at least 3 mm.
• The electrical circuit must be separated from the network by adapted devices, for
example: circuit breakers, fuses or contactors.
• If the appliance is not fitted with an accessible plug, disconnecting means must be
incorporated in the fixed installation, in accordance with the installation regulations.
• The inlet hose must be positioned so that it does not touch any of the hot parts of the hob
or even.
Caution!
• This appliance has only to be connected to a network 230 V~ 50/60 Hz
• Always connect the earth wire.
• Respect the connection diagram.
• The connection box is located underneath at the back of the hob casing. To open the
cover, use a medium screwdriver. Place it in the slits and open the cover.
Mains
230V~1N 50/60Hz
400V~2N 50/60Hz
( * ) calculated with the simultaneous factor following standard EN 60 335-2-6
Setting up the configurations:
For the various kinds of connection, use the brass links which are in the box next to the terminal
block. Except for where the appliance is pre-wired.
Connection
Cable diameter
1 Phase + N
3 x 2,5 mm²
2 Phases + N
4 x 1.5 mm²
Cable
H 05 VV - F
H 05 RR - F
H 05 VV - F
H 05 RR - F
38
Protection calibre
25 A *
16 A *