2.
Adjustments
1
TIME
approximately 5 secs to 15 mins
Twilight switch (LUX)
Night operation
Day and night operation
The intermediate area can be used for various luminosity values
Coverage (METRES)
up to 8 m
Set the control knob (1) for test
operation
The sliding switch (2) on the twilight switch
2
has the following functions:
0 = OFF: always set the switch to this
position when changing a light bulb
3
A = automatic operation: the movement-
detector switches on the light when it
1
detects a movement and switches it off
again after the preselected time – if no
further movement has been detected.
1 = permanent light
Now carry out a movement test by pacing
around the area of coverage, in order to
4
adjust the settings as desired (fig. 4).
195°
Undesired areas can be excluded by using
the supplied masking band (3).