• AUTOMATIC DRAIN SHUT-OFF VALVE
• MANUAL FAST FLUSH VALVE
• DAILY PRODUCTION RATE = 24.22 GPD
• EFFICIENCY RATING
• RECOVERY RATING
• MAX TDS LEVEL (PPM) = 1400
• CAPACITY FOR VOC REDUCTION: 225 GALLONS
• CAPACITY FOR CHLORAMINE, CHLORINE, TASTE & ODOR: 225 GALLONS
• OPERATING PSI OF SUPPLY: 40 - 100 PSI (275 - 689 kPa)
• OPERATING TEMPERATURE: 50 - 100
• FLOWRATE FOR POST FILTER: 1.0 GPM
This system has been tested according to NSF/ANSI 58 for reduction of the
substances listed below. The concentration of the indicated substances in
water entering the system was reduced to a concentration less than or
equal to the permissible limit for water leaving the system, as specified in
NSF/ANSI 58.
LIST OF contaminant
AVERAGE
INFLUENT
CONTAMINANT
CONCENTRATION
(mg/L)
1
ARSENIC
0.31
BARIUM
9.4
CADMIUM
0.031
CHROMIUM
0.31
(HEXAVALENT)
CHROMIUM
9.4
(TRIVALENT)
COPPER
3.0
CYST
130000
2
NITRATE/NITRITE
32
FLUORIDE
9.2
LEAD
0.031
RADIUM 226/228
25 pCi/L
SELENIUM
9.2
TDS
760
TURBIDITY
11 NTU
NSF/ANSI STANDARD 58 TEST CONDITION: 50 ± 3 psi, pH 7.5 ± 0.5, 77 ± 2 ºF
IMPORTANT NOTICE:
READ THIS PERFORMANCE DATA SHEET AND COMPARE
THE CAPABILITIES OF THIS UNIT WITH YOUR ACTUAL
WATER TREATMENT NEEDS. IT IS RECOMMENDED THAT
BEFORE PURCHASING A WATER TREATMENT UNIT, YOU
HAVE YOUR WATER SUPPLY TESTED TO DETERMINE
YOUR ACTUAL WATER TREATMENT NEEDS.
Ultrefiner II - FMV
PREMIUM DRINKING WATER SYSTEM
3
= 27.16%
4
= 44.42%
AVERAGE
AVERAGE
EFFLUENT
PERCENT
CONCENTRATION
CONCENTRATION
REDUCTION
(mg/L)
0.003
99
0.11
98.8
0.0005
98.3
0.003
99
0.11
98.8
0.049
98.4
7
>99.99
7.5
76.2
0.6
93.8
0.0005
98.3
5 pCi/L
75
0.6
93.8
51
93.3
0.2 NTU
98.7
PERFORMANCE DATA SHEET - page 1 of 4
• pH RANGE: 2 - 11
• REPLACEMENT FILTERS:
DESCRIPTION
PRE FILTER
MEMBRANE
POST VOC FILTER
o
o
F (10 - 38
C)
THE UNIT SHOULD BE INSTALLED IN AN AREA NOT AFFECTED BY
EXTREME HEAT, COLD, OR THE ELEMENTS. THIS SYSTEM MUST BE
INSTALLED IN ACCORDANCE WITH ALL APPLICABLE STATE AND LOCAL
LAWS AND REGULATIONS.
DO NOT USE WITH WATER THAT IS MICROBIOLOGICALLY UNSAFE OR
OF UNKNOWN QUALITY WITHOUT ADEQUATE DISINFECTION BEFORE
OR AFTER THE SYSTEM. SYSTEMS CERTIFIED FOR CYST REDUCTION
MAXIMUM
MAY BE USED ON DISINFECTED WATER THAT MAY CONTAIN FILTER-
EFFLUENT
ABLE CYSTS. THE SYSTEM CONTAINS REPLACEMENT COMPONENTS
(mg/L)
CRITICAL FOR EFFECTIVE REDUCTION OF contaminant. THE WATER
SHOULD BE TESTED PERIODICALLY (2 TIMES A YEAR MINIMUM) TO
0.006
VERIFY THAT THE SYSTEM IS PERFORMING SATISFACTORILY.
0.47
REPLACE ULTREFINER II - FMV MEMBRANE CARTRIDGE 24 TO 36
MONTHS AFTER INSTALLATION, DEPENDING ON WATER CONDITIONS.
0.0019
A WATER TEST FOR TDS REDUCTION IS THE BEST INDICATOR OF
MEMBRANE PERFORMANCE. REPLACE THE PREFILTER AND POST FIL-
0.006
TER CARTRIDGES 12 MONTHS AFTER INSTALLATION OR SOONER
DEPENDING ON WATER CONDITIONS.
0.47
THE INLET FEED WATER SHOULD BE FREE FROM IRON, MANGANESE,
0.15
SULFUR.
NSF
CERTIFIED
19
PERFORMANCE DATA SHEET, IS BASED ON OPERATION AT DRAIN
SETTING # 2. CERTIFICATION RESULTS DO NOT APPLY TO OTHER
SETTINGS.
11
WHILE TESTING WAS PERFORMED UNDER STANDARD LABORATORY
1.2
CONDITIONS, ACTUAL PERFORMANCE MAY VARY DUE TO LOCAL
WATER CONDITIONS.
SEE WARRANTY CARD FOR SPECIFIC WARRANTY INFORMATION
0.0019
NOT APPROVED FOR USE IN CALIFORNIA. PLEASE REQUEST
5 pCi/L
CALIFORNIA-SPECIFIC LITERATURE FROM YOUR LOCAL RAIN-
SOFT DEALER.
1.2
NSF/ANSI STANDARD 58 CERTIFIED TO REDUCE CYSTS SUCH AS
CRYPTOSPORIDIUM AND GIARDIA BY MECHANICAL MEANS
60
EPA EST NO: 002623-IL-003
0.4 NTU
C
US
51635
51637
51636
PERFORMANCE
DATA,
AS
SHOWN
Model ULTREFINER II - FMV - BNFP, ULTRE-
FINER II - FMV - BNFV, ULTREFINER II - FMV -
CHFP and ULTREFINER II - FMV - CHFV are
tested and certified by NSF International
against NSF/ANSI 42, 58 & 401 for the reduc-
tion of claims specified on the performance
data sheet
Model ULTREFINER II - FMV - BNFP, ULTRE-
FINER II - FMV - BNFV, ULTREFINER II - FMV
- CHFP and ULTREFINER II - FMV - CHFV are
tested and certified by NSF International to
CSA B483.1 standard.
ITEM#
ON
THE