Basic System Features and Functions
Any time you change a DIP Switch, other than A1, you must reset Persistent
Memory for your new DIP Switch Settings changes to take effect. If you do
not reset Persistent Memory, your system may function improperly.
To reset Persistent Memory:
Power down by disconnecting power source from spa.
Put a jumper across J43, covering both pins. (See illustration below)
(Voir dessin ci-dessous)
Power up by connecting power source to spa.
Wait until "
" is displayed on your panel.
Power down again.
Remove jumper from J43 (May also move to cover 1 pin only)
Power up again.
About Persistent Memory and Time of Day Retention:
This system uses memory that doesn't require a battery to store a variety of
settings. What we refer to as Persistent Memory stores the filter settings,
the set temperature, and the heat mode.
Persistent Memory is not used for Time of Day. Only models with a
Serial Deluxe panel installed (VS5xxDZ and GS5xxDZ) can display the
time. However, during power loss to the spa, the system will lose the
correct time, and reset to 12:00 PM when power is restored.
J43
J23
J50
K6
K1
S1
W1
SWITCHBANK A
T1
F4
FUSE .3A 250V
K3
K2
F2
SWITCHBANK A
J43 on VS5xxZ and VS300 Series Main Board Shown.
J43 on GS5xxZ Series is located in approximately the same position.
F7
FUSE 20A 250V
J47
J29
F1
J20
J6
TST
W7
K5
K8
W2
K9
W3
J1A
J1
J10
J2A
2 3
1
U4
J12
J2
J43
J13
BALBOA INSTRUMENTS, INC.
2-SPD
J60
J22
J44
VS500Z
EXT RLY
J7
J8
J6
P/N 22972 REV D
TST
S1
MADE IN U.S.A
EXT.
AUX. F
VAC
SEN. A
COPYRIGHT 2005
SEN. B
RLY
Power Up Display Sequence
Upon power up, you should see the following on the display:
Three numbers in a row, which are the SSID (the System Software
ID). The third display of these numbers is the Software Version,
which should match the version of your system. For example, if these
three numbers are
Displayed next is: "
a heater between 3 and 6 kW) or " " (indicating the system is
configured for a heater effectively* between 1 and 3 kW).
"
" should appear for all VS models running at 240VAC.
" " should appear for all VS models running at 120VAC, as well
as all GS models. (*A heater which is rated at 4 kW at 240VAC will
function as a 1 kW heater at 120VAC.)
"
" will appear to signal the start of Priming Mode.
At this point, the power up sequence is complete. Refer to the Reference
Card for the VS or GS System model of your spa for information about how
the spa operates from this point on, including how to adjust the Time of
Day if using a Serial Deluxe style panel.
PUMP
J23
SWITCHBANK A
K4
K1
F2
T0.25A 250V
NEUTRAL
NEUTRAL
W1
J58
J57
J26
LINE
BLK AC
HEATER
J43 on VS100/GS100 Series Main Board Shown.
Page 3
, that is a VS511SZ at version 38.
" (indicating the system is configured for
TST
RST
J6
J43
J1
OZONE
J29
K5
HI/LOW
WHT AC
J11
K3
F4
S1
J7
J8
SEN. A
S
SEN. B
55296_97_A
J7
J20
G
C
J18
U4
J8
J1

Publicité

loading

Ce manuel est également adapté pour:

Mp7-vs100-gcak