Specifications

Model
Nominal voltage(s) and
range:
Nominal input frequency
and tolerance:
Nominal output voltage:
Nominal output frequency:
Output voltage regulation
in line mode:
Output voltage regulation
in battery mode:
Nominal output power in
W / VA:
Output voltage waveform:
Maximum output current
@ P . F.
Efficiency with nominal
load:
Maximum operating
altitude at 100% of
nominal power:
Online Overload Capability:
Overload capacity in
battery mode:
Current limitation:
Autonomy time at full load:
Battery recharge time:
Transfer time:
Outlets:
Maximum input current:
21-10-081 932490-Book.indb 8
21-10-081 932490-Book.indb 8
OMNI500ISO
OMNI750ISO
120V~, 81-143V
120V~, 81-143V
60 Hz (+/- 5 Hz)
60 Hz (+/- 5 Hz)
120V~ in line mode
120V~ in line mode
and 115V~ battery
and 115V~ battery
60 Hz (+/-0.5 Hz)
60 Hz (+/-0.5 Hz)
120V~ (+8% / -18%)
120V~ (+8% / -18%)
115V~ (+/- 5%)
115V~ (+/- 5%)
300W / 500VA
500W / 750VA
Sinusoidal in line mode
Sinusoidal in line mode
and quasi-sine (PWM)
and quasi-sine (PWM)
in battery mode
in battery mode
4.2A @ 120V~
4.2A @ 120V~
0.6 P .F.
0.7 P .F.
91%
91%
"6562 ft.
"6562 ft.
(2000 m) above the
(2000 m) above the
sea level"
sea level"
125% for 10 minutes
125% for 10 minutes
105% @ 0.5 seconds
105% @ 0.5 seconds
N/A
N/A
5.4 minutes @ 300W
13.5 minutes @ 500W
4.5 hours
4.5 hours
6 milliseconds typical
6 milliseconds typical
(10 milliseconds max)
(10 milliseconds max)
3x 5-15R outlets
6x 5-15R outlets
with battery backup,
with battery backup,
regulation and surge
regulation and surge
4.8A
5.5A
8
OMNI1000ISO
120V~, 81-143V
60 Hz (+/- 5 Hz)
120V~ in line mode
and 115V~ battery
60 Hz (+/-0.5 Hz)
120V~ (+8% / -18%)
115V~ (+/- 5%)
700W / 1000VA
Sinusoidal in line mode
and quasi-sine (PWM)
in battery mode
5.8A @ 120V~
0.7 P .F.
91%
"6562 ft.
(2000 m) above the
sea level"
125% for 10 minutes
105% @ 0.5 seconds
Input 10A
8 minutes @ 700W
4.5 hours
6 milliseconds typical
(10 milliseconds max)
6x 5-15R outlets
with battery backup,
regulation and surge
7.6A
10/26/2021 1:08:09 PM
10/26/2021 1:08:09 PM

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Omnismart omni750isoOmnismart omni1000iso

Table des Matières