Ariston C 34S G1 EX Mode D'emploi page 4

Masquer les pouces Voir aussi pour C 34S G1 EX:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

GB
AR
Table of burner and nozzle specifications
Table 1
Burner
Fast
(Large)(R)
Semi Fast
(Medium)(S)
Auxiliary
(Small)(A)
Oven
Grill
Supply
Pressures
S S
A
R
C 34S G1 EX
4
Diameter
By-Pass
(mm)
1/100
(mm)
100
41
75
30
51
30
-
46
-
-
Nominal (kPa)
Minimum (kPa)
Maximum (kPa)
Tight control
When installation has been completed, check the
pipe fitting for leaks with a soapy solution. Never use
a flame. Once the connection has been made, ensure
that the flexible metal tube does not touch any moving
parts and is not crushed.
Liquid Gas
Nozzle
1/100
(mm)
nominal
87
70
52
80
75
TECHNICAL DATA
Oven dimensions
34x39x44 cm
(HxWxD)
Volume
58 l
Useful
measurements
width 42 cm
relating to the
depth 44 cm
oven
height 17 cm
compartment
may be adapted for use with any
Burners
type of gas shown on the data
plate.
EC Directives: 2006/95/CE dated
12.12.06 (Low Voltage) and
subsequent amendments -
2004/108/CE dated 15/12/04
(Electromagnetic Compatibility)
and subsequent amendments -
2009/142/EC dated 30/11/09 (Gas)
and subsequent amendments -
93/68/EEC dated 22/07/93 and
subsequent amendments -
2002/96/EC.
1275/2008 (Stand-by/Off mode)
Flow
g/h
minim
220
50
140
25
65
25
204
200
167
-
30
25
35

Publicité

Table des Matières
loading

Table des Matières