Technical Specifications - Airstream TC4-NVS Mode D'emploi

Table des Matières

Publicité

TECHNICAL SPECIFICATIONS

Supply: - 115/230 VAC, (-18%,+8%), 50/60 Hz, overload and overvoltage
protection fuse F6-1A fast blow.
- 12 VDC for AC back-up supply, can activate Stage 2 and alarm
if supplied with DC back-up voltage.
Curtain: OPEN-CLOSE output, 115/230 VAC, 50/60 Hz, 5A winch output,
fuse F1-5A slow blow.
Stage 2: ON-OFF output, 115/230 VAC, 50/60 Hz, 30 VDC, 6A FAN, 10A
RES, fuse F3-10A slow blow.
Alarm: ON-OFF output, 115/230 VAC, 50/60 Hz, 30 VDC, 3A, fuse F4-3A
slow blow.
Probes: Low voltage ( < 5V), isolated from the supply. Operating range:
-40.0° to 120.0°F (-40.0° to 48.9°C). Accuracy: 1.8
o
o
95
F (5
and 35
Enclosure: ABS, moisture and dust-tight.
The room temperature where the controller is located MUST
ALWAYS REMAIN BETWEEN 32
o
C).
o
F (1
o
o
AND 104
F (0
o
C) between 41
o
o
AND 40
C).
TC4-NVS.rev.04
o
and
37

Publicité

Table des Matières
loading

Table des Matières